Electrocatalytic behavior of cobalt phthalocyanine complexes immobilized on glassy carbon electrode towards the reduction of dicrotophos pesticide
- Vilakazi, Sibulelo, Nyokong, Tebello, Fukuda, Takamitsu, Kobayashi, Nagao
- Authors: Vilakazi, Sibulelo , Nyokong, Tebello , Fukuda, Takamitsu , Kobayashi, Nagao
- Date: 2012
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/245832 , vital:51409 , xlink:href="https://doi.org/10.1142/S1088424612501040"
- Description: Electrocatalytic properties of cobalt phthalocyanine (CoPc), cobalt tetra-carboxy phthalocyanine (CoTCPc) and cobalt octa-carboxy (CoOCPc), towards the detection of dicrotophos have been studied. Catalytic behavior towards the reduction of dicrotophos was found to be dependent on the pH, as well as the substitution on the phthalocyanine ring. Strong electron withdrawing groups on the phthalocyanine ring yielded best catalysis as evidenced by the enhancement of the reduction peak current, (~5 fold) compared to the bare glassy carbon electrode. The analysis gave a good detection limit of 1.25 × 10-7 M, and good linearity for the studied concentration range. A high Tafel slope value was obtained, indicating a strong interaction between dicrotophos and the cobalt phthalocyanine complex.
- Full Text:
- Date Issued: 2012
- Authors: Vilakazi, Sibulelo , Nyokong, Tebello , Fukuda, Takamitsu , Kobayashi, Nagao
- Date: 2012
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/245832 , vital:51409 , xlink:href="https://doi.org/10.1142/S1088424612501040"
- Description: Electrocatalytic properties of cobalt phthalocyanine (CoPc), cobalt tetra-carboxy phthalocyanine (CoTCPc) and cobalt octa-carboxy (CoOCPc), towards the detection of dicrotophos have been studied. Catalytic behavior towards the reduction of dicrotophos was found to be dependent on the pH, as well as the substitution on the phthalocyanine ring. Strong electron withdrawing groups on the phthalocyanine ring yielded best catalysis as evidenced by the enhancement of the reduction peak current, (~5 fold) compared to the bare glassy carbon electrode. The analysis gave a good detection limit of 1.25 × 10-7 M, and good linearity for the studied concentration range. A high Tafel slope value was obtained, indicating a strong interaction between dicrotophos and the cobalt phthalocyanine complex.
- Full Text:
- Date Issued: 2012
Voltammetric determination of nitric oxide on cobalt phthalocyanine modified microelectrodes
- Vilakazi, Sibulelo Lea, Nyokong, Tebello
- Authors: Vilakazi, Sibulelo Lea , Nyokong, Tebello
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/291629 , vital:56893 , xlink:href="https://doi.org/10.1016/S0022-0728(01)00583-6"
- Description: The catalytic activity of a carbon fiber microelectrode modified with cobalt phthalocyanine (CoPc-ME) for the detection of nitric oxide in the presence of possible interfering molecules (dopamine and serotonin) is examined. A linear plot is observed for the variation of the catalytic currents with NO concentration in the presence of excess dopamine and serotonin, showing that NO may be determined in the presence of these molecules. However, oxidation currents due to serotonin were found to decrease with increase in NO concentration. The CoPc-ME could also detect NO added to blood or its components, the oxidation currents for NO, however, decreased rapidly with time. The decrease in currents was slower in blood serum, followed by whole blood, with a faster decrease being observed in blood plasma.
- Full Text:
- Date Issued: 2001
- Authors: Vilakazi, Sibulelo Lea , Nyokong, Tebello
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/291629 , vital:56893 , xlink:href="https://doi.org/10.1016/S0022-0728(01)00583-6"
- Description: The catalytic activity of a carbon fiber microelectrode modified with cobalt phthalocyanine (CoPc-ME) for the detection of nitric oxide in the presence of possible interfering molecules (dopamine and serotonin) is examined. A linear plot is observed for the variation of the catalytic currents with NO concentration in the presence of excess dopamine and serotonin, showing that NO may be determined in the presence of these molecules. However, oxidation currents due to serotonin were found to decrease with increase in NO concentration. The CoPc-ME could also detect NO added to blood or its components, the oxidation currents for NO, however, decreased rapidly with time. The decrease in currents was slower in blood serum, followed by whole blood, with a faster decrease being observed in blood plasma.
- Full Text:
- Date Issued: 2001
The effects of carbon nanotubes on the electrocatalysis of hydrogen peroxide by metallo-phthalocyanines
- Mashazi, Philani N, Mugadza, Tawanda, Sosibo, Ndabenhle, Mdluli, Phumlani, Vilakazi, Sibulelo, Nyokong, Tebello
- Authors: Mashazi, Philani N , Mugadza, Tawanda , Sosibo, Ndabenhle , Mdluli, Phumlani , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2011
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/247174 , vital:51553 , xlink:href="https://doi.org/10.1016/j.talanta.2011.07.069"
- Description: The pre-grafted screen-printed gold electrode modified with phenyl-amino monolayer was investigated for covalent immobilization of phenyl-amine functionalized single-walled carbon nanotubes (PA-SWCNT) and metal tetra-amino phthalocyanine (MTAPc) using Schiff-base reactions with benzene-1,4-dicarbaldehyde (BDCA) as cross-linker. The PA-SWCNT and MTAPc modified electrodes were applied as hybrids for electrochemical sensing of H2O2. The step-by-step fabrication of the electrode was followed using electrochemistry, impedance spectroscopy, scanning electron microscopy and Raman spectroscopy and all these techniques confirmed the fabrication and the immobilization of PA-SWCNT, MnTAPc and CoTAPc onto gold surfaces. The apparent electron transfer constant (kapp) showed that the carbon nanotubes and metallo-phthalocyanines hybrids possess good electron transfer properties compared to the bare, pre-grafted and the MTAPc modified gold electrode surfaces without PA-SWCNT. The electrochemical sensing of hydrogen peroxide was successful with PA-SWCNT–MTAPc hybrid systems showing higher electrocatalytic currents compared to the other electrodes. The analytical parameters obtained using chronoamperometry gave good linearity at H2O2 concentrations ranging from 1.0 to 30.0 μmol L−1. The values for the limit of detection (LoD) were found to be of the orders of 10−7 M using the 3δ for all the electrodes. The PA-SWCNT–MTAPc modified SPAuEs were much more sensitive compared to PA–MTAPc modified SPAuEs.
- Full Text:
- Date Issued: 2011
- Authors: Mashazi, Philani N , Mugadza, Tawanda , Sosibo, Ndabenhle , Mdluli, Phumlani , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2011
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/247174 , vital:51553 , xlink:href="https://doi.org/10.1016/j.talanta.2011.07.069"
- Description: The pre-grafted screen-printed gold electrode modified with phenyl-amino monolayer was investigated for covalent immobilization of phenyl-amine functionalized single-walled carbon nanotubes (PA-SWCNT) and metal tetra-amino phthalocyanine (MTAPc) using Schiff-base reactions with benzene-1,4-dicarbaldehyde (BDCA) as cross-linker. The PA-SWCNT and MTAPc modified electrodes were applied as hybrids for electrochemical sensing of H2O2. The step-by-step fabrication of the electrode was followed using electrochemistry, impedance spectroscopy, scanning electron microscopy and Raman spectroscopy and all these techniques confirmed the fabrication and the immobilization of PA-SWCNT, MnTAPc and CoTAPc onto gold surfaces. The apparent electron transfer constant (kapp) showed that the carbon nanotubes and metallo-phthalocyanines hybrids possess good electron transfer properties compared to the bare, pre-grafted and the MTAPc modified gold electrode surfaces without PA-SWCNT. The electrochemical sensing of hydrogen peroxide was successful with PA-SWCNT–MTAPc hybrid systems showing higher electrocatalytic currents compared to the other electrodes. The analytical parameters obtained using chronoamperometry gave good linearity at H2O2 concentrations ranging from 1.0 to 30.0 μmol L−1. The values for the limit of detection (LoD) were found to be of the orders of 10−7 M using the 3δ for all the electrodes. The PA-SWCNT–MTAPc modified SPAuEs were much more sensitive compared to PA–MTAPc modified SPAuEs.
- Full Text:
- Date Issued: 2011
Phthalocyanines and related complexes as electrocatalysts for the detection of nitric oxide
- Nyokong, Tebello, Vilakazi, Sibulelo
- Authors: Nyokong, Tebello , Vilakazi, Sibulelo
- Date: 2003
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/290346 , vital:56741 , xlink:href="https://doi.org/10.1016/S0039-9140(03)00356-4"
- Description: Metallophthalocyanine (MPc) and metalloporphyrin complexes as well as some metalloproteins including myoglobin, hemoglobin, cyanocobalamin and cytochrome c catalyse the detection of nitric oxide (NO). The catalytic process often involve changes in the oxidation state of the catalyst. These complexes catalyse both the reduction and oxidation of NO. MPc complexes containing electroactive central metals such as CoPc and FePc generally show better catalytic activity towards the detection of NO than complexes containing electroinacive central metals. However, the involvement of ring based redox processes was confirmed for the homogenous NO catalysis using CoPc.
- Full Text:
- Date Issued: 2003
- Authors: Nyokong, Tebello , Vilakazi, Sibulelo
- Date: 2003
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/290346 , vital:56741 , xlink:href="https://doi.org/10.1016/S0039-9140(03)00356-4"
- Description: Metallophthalocyanine (MPc) and metalloporphyrin complexes as well as some metalloproteins including myoglobin, hemoglobin, cyanocobalamin and cytochrome c catalyse the detection of nitric oxide (NO). The catalytic process often involve changes in the oxidation state of the catalyst. These complexes catalyse both the reduction and oxidation of NO. MPc complexes containing electroactive central metals such as CoPc and FePc generally show better catalytic activity towards the detection of NO than complexes containing electroinacive central metals. However, the involvement of ring based redox processes was confirmed for the homogenous NO catalysis using CoPc.
- Full Text:
- Date Issued: 2003
Facile deposition of gold nanoparticle thin films on semi-permeable cellulose substrate
- Sosibo, Ndabenhle, Mdluli, Phumlani, Mashazi, Philani N, Tshikhudo, Robert, Skepu, Amanda, Vilakazi, Sibulelo, Nyokong, Tebello
- Authors: Sosibo, Ndabenhle , Mdluli, Phumlani , Mashazi, Philani N , Tshikhudo, Robert , Skepu, Amanda , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2012
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/242638 , vital:51063 , xlink:href="https://doi.org/10.1016/j.matlet.2012.08.043"
- Description: This study reports the facile method for the deposition of gold nanoparticle thin film onto a monoporous semi-permeable cellulose membrane through the diffusion of borohydride ions leading to the reduction of AuCl4− ions. The synthesis of gold nanoparticle thin film was deposited on one side of the membrane that was exposed to AuCl4− ions while the other side containing a reducing agent remained clear. The gold nanoparticle thin film exhibited a broad surface plasmon resonance (SPR) peak at 529 nm. Various characterization techniques were employed and all demonstrated the presence of gold thin film. The reported method represents a simplistic method for the deposition of gold nanoparticle thin films and various other metal nanoparticles may be deposited following this method.
- Full Text:
- Date Issued: 2012
- Authors: Sosibo, Ndabenhle , Mdluli, Phumlani , Mashazi, Philani N , Tshikhudo, Robert , Skepu, Amanda , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2012
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/242638 , vital:51063 , xlink:href="https://doi.org/10.1016/j.matlet.2012.08.043"
- Description: This study reports the facile method for the deposition of gold nanoparticle thin film onto a monoporous semi-permeable cellulose membrane through the diffusion of borohydride ions leading to the reduction of AuCl4− ions. The synthesis of gold nanoparticle thin film was deposited on one side of the membrane that was exposed to AuCl4− ions while the other side containing a reducing agent remained clear. The gold nanoparticle thin film exhibited a broad surface plasmon resonance (SPR) peak at 529 nm. Various characterization techniques were employed and all demonstrated the presence of gold thin film. The reported method represents a simplistic method for the deposition of gold nanoparticle thin films and various other metal nanoparticles may be deposited following this method.
- Full Text:
- Date Issued: 2012
Interaction of nitric oxide with cobalt (II) phthalocyanine
- Vilakazi, Sibulelo L, Nyokong, Tebello
- Authors: Vilakazi, Sibulelo L , Nyokong, Tebello
- Date: 1998
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/293579 , vital:57100 , xlink:href="https://doi.org/10.1016/S0277-5387(98)00244-7"
- Description: The coordination of nitric oxide (NO) to cobalt(II) phthalocyanine (CoPc) in dimethyl sulphoxide (DMSO) has been studied. CoPc coordinates with NO in a 1:1 ratio, forming a CoPc(NO) species. The IR band observed at 1680 cm−1 is assigned to the coordinated NO. In the presence of excess NO, pseudo first order kinetics were followed. The observed rate constant, kf, was determined to be 15.0±0.3 dm−3 mol−1 s−1 and the equilibrium constant was K=5.4±0.4×104dm3 mol−1. Solution or adsorbed CoPc catalyses the reduction of NO. The products of reduction include NH3 and NH2OH.
- Full Text:
- Date Issued: 1998
- Authors: Vilakazi, Sibulelo L , Nyokong, Tebello
- Date: 1998
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/293579 , vital:57100 , xlink:href="https://doi.org/10.1016/S0277-5387(98)00244-7"
- Description: The coordination of nitric oxide (NO) to cobalt(II) phthalocyanine (CoPc) in dimethyl sulphoxide (DMSO) has been studied. CoPc coordinates with NO in a 1:1 ratio, forming a CoPc(NO) species. The IR band observed at 1680 cm−1 is assigned to the coordinated NO. In the presence of excess NO, pseudo first order kinetics were followed. The observed rate constant, kf, was determined to be 15.0±0.3 dm−3 mol−1 s−1 and the equilibrium constant was K=5.4±0.4×104dm3 mol−1. Solution or adsorbed CoPc catalyses the reduction of NO. The products of reduction include NH3 and NH2OH.
- Full Text:
- Date Issued: 1998
Electrochemical impedimetric immunosensor for the detection of measles-specific IgG antibodies after measles infections
- Mashazi, Philani N, Tetyana, Phumlani, Vilakazi, Sibulelo, Nyokong, Tebello
- Authors: Mashazi, Philani N , Tetyana, Phumlani , Vilakazi, Sibulelo , Nyokong, Tebello
- Language: English
- Type: Article
- Identifier: vital:7325 , http://hdl.handle.net/10962/d1020575
- Description: The detection of measles-specific primary antibodies (IgG) using electrochemical impedimetric immunosensors is reported. The optimum conditions for electrode saturation were reached after 40 min for 1 μg ml−1 antibody concentrations. Surface roughness using AFM increased with each immobilization or antigen-antibody reaction step clearly confirming the surface modification and recognition between antigen and antibody. The human serum (HS) and new-born calf serum (NCS) spiked with antigen-specific antibody were studied to mimic the real sample analysis. The HS and NCS sera containing antibodies due to measles exhibited correlation between the increasing antibody serum concentrations and the charge-transfer resistance (electrochemically measured). This work clearly showed the potential use of impedance as the preferred electrochemical method for detecting measles-antibodies in label-free manner. , Original publication is available at http://dx.doi.org/10.1016/j.bios.2013.04.028
- Full Text: false
- Authors: Mashazi, Philani N , Tetyana, Phumlani , Vilakazi, Sibulelo , Nyokong, Tebello
- Language: English
- Type: Article
- Identifier: vital:7325 , http://hdl.handle.net/10962/d1020575
- Description: The detection of measles-specific primary antibodies (IgG) using electrochemical impedimetric immunosensors is reported. The optimum conditions for electrode saturation were reached after 40 min for 1 μg ml−1 antibody concentrations. Surface roughness using AFM increased with each immobilization or antigen-antibody reaction step clearly confirming the surface modification and recognition between antigen and antibody. The human serum (HS) and new-born calf serum (NCS) spiked with antigen-specific antibody were studied to mimic the real sample analysis. The HS and NCS sera containing antibodies due to measles exhibited correlation between the increasing antibody serum concentrations and the charge-transfer resistance (electrochemically measured). This work clearly showed the potential use of impedance as the preferred electrochemical method for detecting measles-antibodies in label-free manner. , Original publication is available at http://dx.doi.org/10.1016/j.bios.2013.04.028
- Full Text: false
A colorimetric probe for dopamine based on gold nanoparticles-electrospun nanofibre composite
- Ngomane, Nokuthula, Torto, Nelson, Krause, Rui W M, Vilakazi, Sibulelo
- Authors: Ngomane, Nokuthula , Torto, Nelson , Krause, Rui W M , Vilakazi, Sibulelo
- Date: 2015
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/195407 , vital:45562 , xlink:href="https://doi.org/10.1016/j.matpr.2015.08.036"
- Description: An easily prepared solid state colorimetric probe for detecting the neurotransmitter dopamine (DA) was developed. The probe, in the form of an electrospun Nylon−6 (N6) nanofibre with embedded un−functionalized gold nanoparticles (UF−AuNPs) produces a clear colour change in the presence of a DA that is detectable by the naked eye. Characterisation of the nanofibre using UV/vis spectroscopy and electron microscopy (TEM) confirmed the formation of the AuNPs in the polymer solution, and that the AuNPs were completely encapsulated within the composite nanofibres before exposure to the analytes. The probe exhibited very high sensitivity towards DA resulting in colour change of the composite fibres from purple to navy blue/black even under low concentrations of DA. The probe was also selective to DA since the colour remained unchanged in the presence of commonly encountered interfering species such as ascorbic acid, uric acid, catechol, epinephrine and norepinephrine. Moreover, the colour change was observed rapid, occurring either immediately on contact with higher concentrations (5 x10−4 M) or within about 3−5 min for the lower concentrations (e.g. 5 x10−7 M). Since this probe does not require the use of any instruments, and is both rapid and stable over time, it can be applied in the field by an inexperienced person.
- Full Text:
- Date Issued: 2015
- Authors: Ngomane, Nokuthula , Torto, Nelson , Krause, Rui W M , Vilakazi, Sibulelo
- Date: 2015
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/195407 , vital:45562 , xlink:href="https://doi.org/10.1016/j.matpr.2015.08.036"
- Description: An easily prepared solid state colorimetric probe for detecting the neurotransmitter dopamine (DA) was developed. The probe, in the form of an electrospun Nylon−6 (N6) nanofibre with embedded un−functionalized gold nanoparticles (UF−AuNPs) produces a clear colour change in the presence of a DA that is detectable by the naked eye. Characterisation of the nanofibre using UV/vis spectroscopy and electron microscopy (TEM) confirmed the formation of the AuNPs in the polymer solution, and that the AuNPs were completely encapsulated within the composite nanofibres before exposure to the analytes. The probe exhibited very high sensitivity towards DA resulting in colour change of the composite fibres from purple to navy blue/black even under low concentrations of DA. The probe was also selective to DA since the colour remained unchanged in the presence of commonly encountered interfering species such as ascorbic acid, uric acid, catechol, epinephrine and norepinephrine. Moreover, the colour change was observed rapid, occurring either immediately on contact with higher concentrations (5 x10−4 M) or within about 3−5 min for the lower concentrations (e.g. 5 x10−7 M). Since this probe does not require the use of any instruments, and is both rapid and stable over time, it can be applied in the field by an inexperienced person.
- Full Text:
- Date Issued: 2015
Design and evaluation of an electrochemical immunosensor for measles serodiagnosis using measles-specific Immunoglobulin G antibodies
- Mashazi, Philani N, Vilakazi, Sibulelo, Nyokong, Tebello
- Authors: Mashazi, Philani N , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2013
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/241705 , vital:50962 , xlink:href="https://doi.org/10.1016/j.talanta.2013.06.036"
- Description: The design of electrochemical immunosensors for the detection of measles-specific antibodies is reported. The measles-antigen modified surface was used as an antibody capture surface. The detection of measles-specific IgG antibodies was accomplished using the voltammetric method and horse-radish peroxidase (HRP) labeled secondary antibody (anti-IgG) as a detecting antibody. The potential applications of the designed immunosensor were evaluated in buffer and serum solutions. The immunosensor exhibited good linearity at concentrations less than 100 ng mL−1 with R2=0.997 and the limit of detection of 6.60 ng mL−1 at 3σ. The potential application of the immunosensor was evaluated in the deliberately infected human and newborn calf serum samples with measles-IgG antibody mimicking real-life samples. The designed electrochemical immunosensor could differentiate between infected and un-infected serum samples as higher catalytic currents were obtained for infected serum samples.
- Full Text:
- Date Issued: 2013
- Authors: Mashazi, Philani N , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2013
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/241705 , vital:50962 , xlink:href="https://doi.org/10.1016/j.talanta.2013.06.036"
- Description: The design of electrochemical immunosensors for the detection of measles-specific antibodies is reported. The measles-antigen modified surface was used as an antibody capture surface. The detection of measles-specific IgG antibodies was accomplished using the voltammetric method and horse-radish peroxidase (HRP) labeled secondary antibody (anti-IgG) as a detecting antibody. The potential applications of the designed immunosensor were evaluated in buffer and serum solutions. The immunosensor exhibited good linearity at concentrations less than 100 ng mL−1 with R2=0.997 and the limit of detection of 6.60 ng mL−1 at 3σ. The potential application of the immunosensor was evaluated in the deliberately infected human and newborn calf serum samples with measles-IgG antibody mimicking real-life samples. The designed electrochemical immunosensor could differentiate between infected and un-infected serum samples as higher catalytic currents were obtained for infected serum samples.
- Full Text:
- Date Issued: 2013
Electrocatalytic properties of vitamin B12 towards oxidation and reduction of nitric oxide
- Vilakazi, Sibulelo Lea, Nyokong, Tebello
- Authors: Vilakazi, Sibulelo Lea , Nyokong, Tebello
- Date: 2000
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/293196 , vital:57064 , xlink:href="https://doi.org/10.1016/S0013-4686(00)00628-9"
- Description: This paper reports on the catalytic behaviour of cyanocobalamin (VB12) towards the reduction and oxidation of nitric oxide. When VB12 is adsorbed on glassy carbon electrodes, it catalyses the reduction of nitric oxide (NO) in pH 4 and 9 buffers. In the absence of NO, cyclic voltammetry shows that VB12 is reduced by a one-step two-electron reduction from CoIII to the CoI species. Addition of NO at pH 9 to solutions of VB12 resulted in the splitting of the cyclic voltammetry peaks as a result of a consecutive one-electron reduction of the central CoIII metal in VB12 to CoII and finally to CoI. The catalytic peak for oxidation of NO on a glassy carbon electrode modified with VB12 was observed at 1.21 V versus Ag∣AgCl, at pH 9. The products of the catalytic reduction of nitric oxide include ammonia and hydroxylamine.
- Full Text:
- Date Issued: 2000
- Authors: Vilakazi, Sibulelo Lea , Nyokong, Tebello
- Date: 2000
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/293196 , vital:57064 , xlink:href="https://doi.org/10.1016/S0013-4686(00)00628-9"
- Description: This paper reports on the catalytic behaviour of cyanocobalamin (VB12) towards the reduction and oxidation of nitric oxide. When VB12 is adsorbed on glassy carbon electrodes, it catalyses the reduction of nitric oxide (NO) in pH 4 and 9 buffers. In the absence of NO, cyclic voltammetry shows that VB12 is reduced by a one-step two-electron reduction from CoIII to the CoI species. Addition of NO at pH 9 to solutions of VB12 resulted in the splitting of the cyclic voltammetry peaks as a result of a consecutive one-electron reduction of the central CoIII metal in VB12 to CoII and finally to CoI. The catalytic peak for oxidation of NO on a glassy carbon electrode modified with VB12 was observed at 1.21 V versus Ag∣AgCl, at pH 9. The products of the catalytic reduction of nitric oxide include ammonia and hydroxylamine.
- Full Text:
- Date Issued: 2000
Interaction of nitric oxide with cobalt (II) tetrasulfophthalocyanine
- Vilakazi, Sibulelo, Nyokong, Tebello
- Authors: Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2000
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/293235 , vital:57067 , xlink:href="https://doi.org/10.1016/S0277-5387(99)00373-3"
- Description: The interaction of nitric oxide (NO) with cobalt(II) tetrasulfophthalocyanine [Co(II)TSPc]4−) has been studied. Coordination of NO is accompanied by electron transfer from the central metal in [Co(II)TSPc]4−, the resulting complex being represented as [(NO−)Co(III)TSPc]4−. The rate constant for the formation of this species is kf=142±7 dm3 mol−1 s−1 and an equilibrium constant of 3.0±0.5×105 dm3 mol−1 was obtained. When adsorbed to a glassy carbon electrode, [Co(II)TSPc]4− catalyses the oxidation and reduction of NO, with a detection limit of the order of 10−9 mol dm−3. Ammonia and hydroxylamine are some of the reduction products obtained for the reduction of NO on [Co(II)TSPc]4−-modified glassy carbon electrodes.
- Full Text:
- Date Issued: 2000
- Authors: Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2000
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/293235 , vital:57067 , xlink:href="https://doi.org/10.1016/S0277-5387(99)00373-3"
- Description: The interaction of nitric oxide (NO) with cobalt(II) tetrasulfophthalocyanine [Co(II)TSPc]4−) has been studied. Coordination of NO is accompanied by electron transfer from the central metal in [Co(II)TSPc]4−, the resulting complex being represented as [(NO−)Co(III)TSPc]4−. The rate constant for the formation of this species is kf=142±7 dm3 mol−1 s−1 and an equilibrium constant of 3.0±0.5×105 dm3 mol−1 was obtained. When adsorbed to a glassy carbon electrode, [Co(II)TSPc]4− catalyses the oxidation and reduction of NO, with a detection limit of the order of 10−9 mol dm−3. Ammonia and hydroxylamine are some of the reduction products obtained for the reduction of NO on [Co(II)TSPc]4−-modified glassy carbon electrodes.
- Full Text:
- Date Issued: 2000
Electrochemical impedimetric immunosensor for the detection of measles-specific IgG antibodies after measles infections
- Mashazi, Philani N, Tetyana, Phumlani, Vilakazi, Sibulelo, Nyokong, Tebello
- Authors: Mashazi, Philani N , Tetyana, Phumlani , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2013
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/241677 , vital:50960 , xlink:href="https://doi.org/10.1016/j.bios.2013.04.028"
- Description: The detection of measles-specific primary antibodies (IgG) using electrochemical impedimetric immunosensors is reported. The optimum conditions for electrode saturation were reached after 40 min for 1 μg ml−1 antibody concentrations. Surface roughness using AFM increased with each immobilization or antigen-antibody reaction step clearly confirming the surface modification and recognition between antigen and antibody. The human serum (HS) and new-born calf serum (NCS) spiked with antigen-specific antibody were studied to mimic the real sample analysis. The HS and NCS sera containing antibodies due to measles exhibited correlation between the increasing antibody serum concentrations and the charge-transfer resistance (electrochemically measured). This work clearly showed the potential use of impedance as the preferred electrochemical method for detecting measles-antibodies in label-free manner.
- Full Text:
- Date Issued: 2013
- Authors: Mashazi, Philani N , Tetyana, Phumlani , Vilakazi, Sibulelo , Nyokong, Tebello
- Date: 2013
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/241677 , vital:50960 , xlink:href="https://doi.org/10.1016/j.bios.2013.04.028"
- Description: The detection of measles-specific primary antibodies (IgG) using electrochemical impedimetric immunosensors is reported. The optimum conditions for electrode saturation were reached after 40 min for 1 μg ml−1 antibody concentrations. Surface roughness using AFM increased with each immobilization or antigen-antibody reaction step clearly confirming the surface modification and recognition between antigen and antibody. The human serum (HS) and new-born calf serum (NCS) spiked with antigen-specific antibody were studied to mimic the real sample analysis. The HS and NCS sera containing antibodies due to measles exhibited correlation between the increasing antibody serum concentrations and the charge-transfer resistance (electrochemically measured). This work clearly showed the potential use of impedance as the preferred electrochemical method for detecting measles-antibodies in label-free manner.
- Full Text:
- Date Issued: 2013
Mohair and wool fibre surface structure and lustre determination
- Ndlovu, Ntombizikhona Beaulah
- Authors: Ndlovu, Ntombizikhona Beaulah
- Date: 2011
- Subjects: Mohair and wool fibre -- Lustre
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:18484 , http://hdl.handle.net/11260/d1006641
- Description: Textiles have always been one of the essential materials for people and have a great variety of uses such as in clothing, agriculture, medical, automotive and aerospace applications. The sort of properties needed for any type of fabric basically depend on the structure of the fibre surface. Of many geometric attributes that can be used to describe the surface appearance of a fibre, yarn, or fabric sample, one of the more common is lustre. Mohair and wool fibre surface structure have been studied using optical microscopy and Atomic Force Microscopy (AFM). Optical microscopy was also used to take fibre diameter measurements. Another technique, goniophotometry, was used to make quantitative lustre measurements of mohair and wool fibres. The surface structure of mohair has got a faint pattern of scales where the scales are generally unpronounced or flat and relatively long. Wool has got a scaly surface structure where the scales overlap leading to interlocking of fibres. The scale configuration on the surface of mohair and wool fibres also differs. A qualitative connection between fibre lustre and the fibre surface structure was found. Because of its smooth surface relative to that of wool, mohair reflects a greater amount of incident light specularly whereas wool reflects most of the incident light diffusely. In general, mohair fibres have a higher lustre than wool due to its less prominent cuticle structure found on its surface. Furthermore, mohair fibres with the smallest diameters give an even higher lustre.
- Full Text:
- Date Issued: 2011
- Authors: Ndlovu, Ntombizikhona Beaulah
- Date: 2011
- Subjects: Mohair and wool fibre -- Lustre
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:18484 , http://hdl.handle.net/11260/d1006641
- Description: Textiles have always been one of the essential materials for people and have a great variety of uses such as in clothing, agriculture, medical, automotive and aerospace applications. The sort of properties needed for any type of fabric basically depend on the structure of the fibre surface. Of many geometric attributes that can be used to describe the surface appearance of a fibre, yarn, or fabric sample, one of the more common is lustre. Mohair and wool fibre surface structure have been studied using optical microscopy and Atomic Force Microscopy (AFM). Optical microscopy was also used to take fibre diameter measurements. Another technique, goniophotometry, was used to make quantitative lustre measurements of mohair and wool fibres. The surface structure of mohair has got a faint pattern of scales where the scales are generally unpronounced or flat and relatively long. Wool has got a scaly surface structure where the scales overlap leading to interlocking of fibres. The scale configuration on the surface of mohair and wool fibres also differs. A qualitative connection between fibre lustre and the fibre surface structure was found. Because of its smooth surface relative to that of wool, mohair reflects a greater amount of incident light specularly whereas wool reflects most of the incident light diffusely. In general, mohair fibres have a higher lustre than wool due to its less prominent cuticle structure found on its surface. Furthermore, mohair fibres with the smallest diameters give an even higher lustre.
- Full Text:
- Date Issued: 2011
Un-functionalized gold nanoparticles as a simple colorimetric probe for sensitive and selective detection of dopamine
- Khanyile, Nokuthula, Krause, Rui W M, Vilakazi, Sibulelo, Torto, Nelson
- Authors: Khanyile, Nokuthula , Krause, Rui W M , Vilakazi, Sibulelo , Torto, Nelson
- Date: 2019
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/195048 , vital:45522 , xlink:href="http://dx.doi.org/10.17159/0379-4350/2019/v72a27"
- Description: A dopamine (DA) colorimetric probe based on the growth and aggregation of un-functionalized gold nanoparticles (AuNPs) is reported. Upon addition of AuNPs to dopamine at various concentrations, the shape, size and colour change of the nanoparticles results in spectral shifts to higher wavelengths and hence colour change is the mode of detection. The colour change can be easily observed by the naked eye from as low as 5.0 nM DA, even under sub-optimal conditions. Under optimal pH conditions the calculated limit of detection was 2.5 nM (3σ). The probe was successfully applied to whole blood sample and showed good selectivity and sensitivity towards DA. The simple, sensitive and selective probe could be an excellent alternative for on-site and immediate detection of DA without the use of instrumentation and would thus be useful for rapid diagnostic applications.
- Full Text:
- Date Issued: 2019
- Authors: Khanyile, Nokuthula , Krause, Rui W M , Vilakazi, Sibulelo , Torto, Nelson
- Date: 2019
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/195048 , vital:45522 , xlink:href="http://dx.doi.org/10.17159/0379-4350/2019/v72a27"
- Description: A dopamine (DA) colorimetric probe based on the growth and aggregation of un-functionalized gold nanoparticles (AuNPs) is reported. Upon addition of AuNPs to dopamine at various concentrations, the shape, size and colour change of the nanoparticles results in spectral shifts to higher wavelengths and hence colour change is the mode of detection. The colour change can be easily observed by the naked eye from as low as 5.0 nM DA, even under sub-optimal conditions. Under optimal pH conditions the calculated limit of detection was 2.5 nM (3σ). The probe was successfully applied to whole blood sample and showed good selectivity and sensitivity towards DA. The simple, sensitive and selective probe could be an excellent alternative for on-site and immediate detection of DA without the use of instrumentation and would thus be useful for rapid diagnostic applications.
- Full Text:
- Date Issued: 2019
Agreement and coordination in XiTsonga, SeSotho and IsiXhosa: an optimality theoretic perspective
- Authors: Mitchley, Hazel
- Date: 2016
- Language: English
- Type: Thesis , Masters , MA
- Identifier: http://hdl.handle.net/10962/3423 , vital:20491
- Description: This thesis provides a unified Optimality Theoretic analysis of subject-verb agreement with coordinated preverbal subjects in three Southern Bantu languages: Xitsonga (S53), Sesotho (S33), and isiXhosa (S41). This analysis is then used to formulate a typology of agreement resolution strategies and the contexts which trigger them. Although some accounts in the Bantu literature suggest that agreement with coordinate structures is avoided by speakers (e.g. Schadeberg 1992, Voeltz 1971) especially when conjuncts are from different noun classes, I show that there is ample evidence to the contrary, and that the subject marker used is dependent on several factors, including (i) the [-HUMAN] specification on the conjuncts, (ii) whether the conjuncts are singular or plural, (iii) whether or not the conjuncts both carry the same noun class feature, and (iv) the order of the conjuncts. This thesis shows that there are various agreement resolution strategies which can beused: 1) agreement with the [+HUMAN] feature on the conjuncts, 2) agreement with the[-HUMAN] feature on the conjuncts, 3) agreement with the noun class feature on both conjuncts, 4) agreement with the noun class feature on the conjunct closest to the verb, and 5) agreement with the noun class feature on the conjunct furthest from the verb. Not all of these strategies are used by all languages, nor are these strategies interchangeable in the languages which do use them – instead, multiple factors conspire to trigger the use of a specific agreement strategy within a specific agreement featural context. I show that these effects can be captured using Optimality Theory (Prince and Smolensky 2004). The analysis makes use of seven constraints: RES#, MAX[+H], MAX[-H], DEP[-H], MAXNC, DEPNC, and AGREECLOSEST. The hierarchical ranking of these constraints not only accounts for the confinement of particular strategies to specific agreement featural contexts within a language, but also accounts for the cross-linguistic differences in the use of these strategies. I end off by examining the typological implications which follow from the OT analysis provided in this thesis.
- Full Text:
- Date Issued: 2016
- Authors: Mitchley, Hazel
- Date: 2016
- Language: English
- Type: Thesis , Masters , MA
- Identifier: http://hdl.handle.net/10962/3423 , vital:20491
- Description: This thesis provides a unified Optimality Theoretic analysis of subject-verb agreement with coordinated preverbal subjects in three Southern Bantu languages: Xitsonga (S53), Sesotho (S33), and isiXhosa (S41). This analysis is then used to formulate a typology of agreement resolution strategies and the contexts which trigger them. Although some accounts in the Bantu literature suggest that agreement with coordinate structures is avoided by speakers (e.g. Schadeberg 1992, Voeltz 1971) especially when conjuncts are from different noun classes, I show that there is ample evidence to the contrary, and that the subject marker used is dependent on several factors, including (i) the [-HUMAN] specification on the conjuncts, (ii) whether the conjuncts are singular or plural, (iii) whether or not the conjuncts both carry the same noun class feature, and (iv) the order of the conjuncts. This thesis shows that there are various agreement resolution strategies which can beused: 1) agreement with the [+HUMAN] feature on the conjuncts, 2) agreement with the[-HUMAN] feature on the conjuncts, 3) agreement with the noun class feature on both conjuncts, 4) agreement with the noun class feature on the conjunct closest to the verb, and 5) agreement with the noun class feature on the conjunct furthest from the verb. Not all of these strategies are used by all languages, nor are these strategies interchangeable in the languages which do use them – instead, multiple factors conspire to trigger the use of a specific agreement strategy within a specific agreement featural context. I show that these effects can be captured using Optimality Theory (Prince and Smolensky 2004). The analysis makes use of seven constraints: RES#, MAX[+H], MAX[-H], DEP[-H], MAXNC, DEPNC, and AGREECLOSEST. The hierarchical ranking of these constraints not only accounts for the confinement of particular strategies to specific agreement featural contexts within a language, but also accounts for the cross-linguistic differences in the use of these strategies. I end off by examining the typological implications which follow from the OT analysis provided in this thesis.
- Full Text:
- Date Issued: 2016
Gold nanoparticle–based colorimetric probes for dopamine detection
- Authors: Ngomane, Nokuthula
- Date: 2016
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4565 , http://hdl.handle.net/10962/d1021261
- Description: Colorimetric probes have become important tools in analysis and biomedical technology. This thesis reports on the development of such probes for the detection of dopamine (DA). Liquid and different solid state probes were developed utilizing un–functionalized gold nanoparticles (UF–AuNPs). The liquid state probe is based on the growth and aggregation of the UF–AuNPs in the presence of DA. Upon addition of the UF–AuNPs to various concentrations of DA, the shape, size and colour change results in spectral shifts from lower to higher wavelengths. The analyte can be easily monitored by the naked eye from 5.0 nM DA with a calculated limit of detection of 2.5 nM (3σ) under optimal pH. Ascorbic acid (AA) has a potential to interfere with DA detection in solution since it is often present in biological fluids, but in this case the interference was limited to solutions where its concentration was beyond 200 times greater than that of DA. Since most of the previously reported colorimetric probes, especially those for DA are solution based, the main focus of the thesis was in the development of a solid state based colorimetric probe in the form of nanofibre mats. To overcome the interference challenges experienced in the solution studies (the interference by high concentrations of AA), the suitability of molecularly imprinted polymers (MIPs) for the selective detection of DA was investigated. The results showed that the MIPs produced did not play a significant role in enhancing the selectivity towards DA. A probe composed of just the UF–AuNPs and Nylon–6 (UF–AuNPs + N6) was also developed. The UF–AuNPs were synthesized following an in situ reduction method. The probe was only selective to DA and insensitive to other catecholamines at physiological pH. Thus, the probe did not require any addition functionalities to achieve selectivity and sensitive to DA. The liquid state probe and the composite UF–AuNPs + N6 nanofibre probe were successfully applied to a whole blood sample and showed good selectivity towards DA. The simple, sensitive and selective probe could be an excellent alternative for on–site and immediate detection of DA without the use of instrumentation. For quantification of DA using the solid state probe, open–source software imageJ was used to assist in the analysis of the nanofibre colours. It was observed that the intensity of the colour increased with the increase in concentration of DA in a linear fashion. The use of imageJ can also be a great alternative where the colour changes are not so clear or for visually impaired people. The solid state probe developed can detect DA qualitatively and quantitatively. The work also forms a good foundation for development of such probes for other analyte.
- Full Text:
- Date Issued: 2016
- Authors: Ngomane, Nokuthula
- Date: 2016
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4565 , http://hdl.handle.net/10962/d1021261
- Description: Colorimetric probes have become important tools in analysis and biomedical technology. This thesis reports on the development of such probes for the detection of dopamine (DA). Liquid and different solid state probes were developed utilizing un–functionalized gold nanoparticles (UF–AuNPs). The liquid state probe is based on the growth and aggregation of the UF–AuNPs in the presence of DA. Upon addition of the UF–AuNPs to various concentrations of DA, the shape, size and colour change results in spectral shifts from lower to higher wavelengths. The analyte can be easily monitored by the naked eye from 5.0 nM DA with a calculated limit of detection of 2.5 nM (3σ) under optimal pH. Ascorbic acid (AA) has a potential to interfere with DA detection in solution since it is often present in biological fluids, but in this case the interference was limited to solutions where its concentration was beyond 200 times greater than that of DA. Since most of the previously reported colorimetric probes, especially those for DA are solution based, the main focus of the thesis was in the development of a solid state based colorimetric probe in the form of nanofibre mats. To overcome the interference challenges experienced in the solution studies (the interference by high concentrations of AA), the suitability of molecularly imprinted polymers (MIPs) for the selective detection of DA was investigated. The results showed that the MIPs produced did not play a significant role in enhancing the selectivity towards DA. A probe composed of just the UF–AuNPs and Nylon–6 (UF–AuNPs + N6) was also developed. The UF–AuNPs were synthesized following an in situ reduction method. The probe was only selective to DA and insensitive to other catecholamines at physiological pH. Thus, the probe did not require any addition functionalities to achieve selectivity and sensitive to DA. The liquid state probe and the composite UF–AuNPs + N6 nanofibre probe were successfully applied to a whole blood sample and showed good selectivity towards DA. The simple, sensitive and selective probe could be an excellent alternative for on–site and immediate detection of DA without the use of instrumentation. For quantification of DA using the solid state probe, open–source software imageJ was used to assist in the analysis of the nanofibre colours. It was observed that the intensity of the colour increased with the increase in concentration of DA in a linear fashion. The use of imageJ can also be a great alternative where the colour changes are not so clear or for visually impaired people. The solid state probe developed can detect DA qualitatively and quantitatively. The work also forms a good foundation for development of such probes for other analyte.
- Full Text:
- Date Issued: 2016
Predictors of consent to cell line creation and immortalisation in a South African schizophrenia genomics study
- Campbell, Megan M, de Vries, Jantina, Mqulwana, Sibonile G, Mndini, Michael M, Ntola, Odwa A, Jonker, Deborah, Malan, Megan, Pretorius, Adele, Zingela, Zukiswa, van Wyk, Stephanus, Stein, Dan J, Susser, Ezra
- Authors: Campbell, Megan M , de Vries, Jantina , Mqulwana, Sibonile G , Mndini, Michael M , Ntola, Odwa A , Jonker, Deborah , Malan, Megan , Pretorius, Adele , Zingela, Zukiswa , van Wyk, Stephanus , Stein, Dan J , Susser, Ezra
- Date: 2018
- Language: English
- Type: Journal Article
- Identifier: http://hdl.handle.net/11260/5232 , vital:44412
- Full Text:
- Authors: Campbell, Megan M , de Vries, Jantina , Mqulwana, Sibonile G , Mndini, Michael M , Ntola, Odwa A , Jonker, Deborah , Malan, Megan , Pretorius, Adele , Zingela, Zukiswa , van Wyk, Stephanus , Stein, Dan J , Susser, Ezra
- Date: 2018
- Language: English
- Type: Journal Article
- Identifier: http://hdl.handle.net/11260/5232 , vital:44412
- Full Text:
Catalytic behaviour of metallophthalocyanines towards the detection of nitric oxide
- Authors: Vilakazi, Lea Sibulelo
- Date: 2002
- Subjects: Electrochemistry Nitric oxide
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4418 , http://hdl.handle.net/10962/d1006852
- Description: Electrocatalytic reduction and oxidation of nitric oxide (NO) using cobalt phthalocyanine complexes have been studied and compared to vitamin B₁₂ and other metallophthalocyanine (MPc) complexes. Modifying a glassy carbon electrode with these complexes resulted in improved sensitivity of the electrode allowing detection of NO to 10⁻⁹ mol dm⁻³. The mechanisms of catalysis were studied. Electrocatalysis of NO involves coordination of NO to the MPc complex. Hence catalytic activity is affected by the nature of the metal center. However coordination of NO to the MPc complex has to be reversible to eliminate poisoning of the electrode. Though FePc gave the best sensitivity and lowered the reduction potential more than CoPc, the strong Fe-NO bond resulted in the poisoning of the electrode hence, rendering the electrode unstable. Rate constants for NO coordination to the MPc complexes were studied. These rates were smaller than the studied NO porphyrin coordination rates. Electrocatalytic reduction of NO using MPc complexes involves a transfer of an electron from the metal center to the NO ligand. Hence, substitution of electron-donating grohps on the cobalt pthalocyanine complex resulted in improved sensitivity and catalytic activity. A CoPc modified microelectrode (11μm) was used to monitor NO in human blood components and to detect NO in a rat brain. Detections of NO were also done in aqueous solutions in the presence of interfering species such as dopamine and serotonin. An interaction between NO and serotonin was observed.
- Full Text:
- Date Issued: 2002
- Authors: Vilakazi, Lea Sibulelo
- Date: 2002
- Subjects: Electrochemistry Nitric oxide
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4418 , http://hdl.handle.net/10962/d1006852
- Description: Electrocatalytic reduction and oxidation of nitric oxide (NO) using cobalt phthalocyanine complexes have been studied and compared to vitamin B₁₂ and other metallophthalocyanine (MPc) complexes. Modifying a glassy carbon electrode with these complexes resulted in improved sensitivity of the electrode allowing detection of NO to 10⁻⁹ mol dm⁻³. The mechanisms of catalysis were studied. Electrocatalysis of NO involves coordination of NO to the MPc complex. Hence catalytic activity is affected by the nature of the metal center. However coordination of NO to the MPc complex has to be reversible to eliminate poisoning of the electrode. Though FePc gave the best sensitivity and lowered the reduction potential more than CoPc, the strong Fe-NO bond resulted in the poisoning of the electrode hence, rendering the electrode unstable. Rate constants for NO coordination to the MPc complexes were studied. These rates were smaller than the studied NO porphyrin coordination rates. Electrocatalytic reduction of NO using MPc complexes involves a transfer of an electron from the metal center to the NO ligand. Hence, substitution of electron-donating grohps on the cobalt pthalocyanine complex resulted in improved sensitivity and catalytic activity. A CoPc modified microelectrode (11μm) was used to monitor NO in human blood components and to detect NO in a rat brain. Detections of NO were also done in aqueous solutions in the presence of interfering species such as dopamine and serotonin. An interaction between NO and serotonin was observed.
- Full Text:
- Date Issued: 2002
Electrospun fibre based colorimetric probes for biological molecules
- Authors: Mudabuka, Boitumelo
- Date: 2014
- Subjects: Nanofibers , Vitamin C , Dopamine
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4535 , http://hdl.handle.net/10962/d1016354
- Description: The thesis reports the use of electrospun nanofibres as a platform for the development of colorimetric probes. Three colorimetric probes in the form of electrospun nanofibre test strips were developed for the selective detection of ascorbic acid and dopamine because they are crucial biomolecules for physiological processes in human metabolism and usually coexist in biological samples. The simultaneous detection of the biomolecules is very important as their abnormal concentration levels would lead to diseases such as Parkinson's and schizophrenia. Different methods of incorporating detector agents into the nanofibre were exploited for the detection of the biomolecules. The methods included physical incorporation of nanoparticles, covalent bonding of ligand/dyes through surface modification of the fibres. The first colorimetric test strip for ascorbic acid was based on copper-gold alloy nanoparticles prepared in-situ and hosted in nylon6. The test strip showed selectivity in detecting ascorbic acid in the pH range 2 – 7. The suitability of fibres in hosting copper-gold alloy nanoparticles for the colorimetric detection of ascorbic acid was investigated using nylon6, poly(vinyl benzyl chloride)-styrene and cellulose acetate based test strips. All the test strips exhibited leaching and the nylon6 based test strip was found to be thermally stable up to 60 ˚C. The colorimetric performance of the test strips was maintained and neither was colour decay exhibited after 10 months of storage in a shelf. The test strip achieved an eye-ball limit of detection of 1.76 x10-2 mg L-1 and its suitability was demonstrated by the determination of ascorbic acid in fruit juices, urine, serum, and vitamin C tablets. The second colorimetric test strip for ascorbic acid and dopamine employed prussian blue synthesised in-situ in nylon6. Ascorbic acid turned the deep blue test strip to light blue at pH 3, and a faded navy blue colour at a pH range of 6 - 7 while dopamine changed the strip to purple at the same pH range. The versatility of the test strip was demonstrated by detecting ascorbic acid in commercial fruit juices as well as by detecting ascorbic acid as well as dopamine in fortified urine. The eye-ball detection limit of the Prussian blue test strip for ascorbic acid and dopamine was 17.6 mg L-1 and 18.9 mg L-1, respectively. The third method involved a covalent approach, where poly(vinylbenzyl chloride) nanofibers were post functionalised with 2-(2′-pyridyl)-imidazole and iron(III) for the selective detection of ascorbic acid and dopamine. The eye-ball detection limit for ascorbic acid and dopamine was 17.6 mg L-1 and 18.9 mg L-1, respectively. The test strip was selective for dopamine, but the detection of ascorbic acid suffered from interference by glutathione. The application of the test strips was nevertheless demonstrated by the detection of ascorbic acid in fruit juices and dopamine in fortified urine. The developed test strips employing the three approaches were applied without sample pre-treatment and use of supporting equipment.
- Full Text:
- Date Issued: 2014
- Authors: Mudabuka, Boitumelo
- Date: 2014
- Subjects: Nanofibers , Vitamin C , Dopamine
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4535 , http://hdl.handle.net/10962/d1016354
- Description: The thesis reports the use of electrospun nanofibres as a platform for the development of colorimetric probes. Three colorimetric probes in the form of electrospun nanofibre test strips were developed for the selective detection of ascorbic acid and dopamine because they are crucial biomolecules for physiological processes in human metabolism and usually coexist in biological samples. The simultaneous detection of the biomolecules is very important as their abnormal concentration levels would lead to diseases such as Parkinson's and schizophrenia. Different methods of incorporating detector agents into the nanofibre were exploited for the detection of the biomolecules. The methods included physical incorporation of nanoparticles, covalent bonding of ligand/dyes through surface modification of the fibres. The first colorimetric test strip for ascorbic acid was based on copper-gold alloy nanoparticles prepared in-situ and hosted in nylon6. The test strip showed selectivity in detecting ascorbic acid in the pH range 2 – 7. The suitability of fibres in hosting copper-gold alloy nanoparticles for the colorimetric detection of ascorbic acid was investigated using nylon6, poly(vinyl benzyl chloride)-styrene and cellulose acetate based test strips. All the test strips exhibited leaching and the nylon6 based test strip was found to be thermally stable up to 60 ˚C. The colorimetric performance of the test strips was maintained and neither was colour decay exhibited after 10 months of storage in a shelf. The test strip achieved an eye-ball limit of detection of 1.76 x10-2 mg L-1 and its suitability was demonstrated by the determination of ascorbic acid in fruit juices, urine, serum, and vitamin C tablets. The second colorimetric test strip for ascorbic acid and dopamine employed prussian blue synthesised in-situ in nylon6. Ascorbic acid turned the deep blue test strip to light blue at pH 3, and a faded navy blue colour at a pH range of 6 - 7 while dopamine changed the strip to purple at the same pH range. The versatility of the test strip was demonstrated by detecting ascorbic acid in commercial fruit juices as well as by detecting ascorbic acid as well as dopamine in fortified urine. The eye-ball detection limit of the Prussian blue test strip for ascorbic acid and dopamine was 17.6 mg L-1 and 18.9 mg L-1, respectively. The third method involved a covalent approach, where poly(vinylbenzyl chloride) nanofibers were post functionalised with 2-(2′-pyridyl)-imidazole and iron(III) for the selective detection of ascorbic acid and dopamine. The eye-ball detection limit for ascorbic acid and dopamine was 17.6 mg L-1 and 18.9 mg L-1, respectively. The test strip was selective for dopamine, but the detection of ascorbic acid suffered from interference by glutathione. The application of the test strips was nevertheless demonstrated by the detection of ascorbic acid in fruit juices and dopamine in fortified urine. The developed test strips employing the three approaches were applied without sample pre-treatment and use of supporting equipment.
- Full Text:
- Date Issued: 2014
Electrochemical sensing and immunosensing using metallophthalocyanines and biomolecular modified surfaces
- Authors: Mashazi, Philani Nkosinathi
- Date: 2012
- Subjects: Phthalocyanines , Electrochemistry , Electrodes, Enzyme , Measles -- Measurement
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:5580 , http://hdl.handle.net/10962/d1018248
- Description: The synthesis of cobalt and manganese phthalocyanine complexes bearing eight hexylthio and four amino substituents was carried out. The formation of thin films of these complexes using different modification methods was also studied. Hexylthio functionalized metallophthalocyanine complexes were immobilized onto gold electrode surfaces using the self-assembly techniques. Surface modifications using cobalt and manganese tetraamino phthalocyanine as polymers, monolayers (onto electrografted surfaces) and as carbon nanotube – metallophthalocyanine conjugates was also carried out. The new method of modifying gold electrodes with metal tetraamino phthalocyanine complexes was investigated. The modified electrode surfaces were studied for their electrocatalytic properties and as potential electrochemical sensors for the detection of hydrogen peroxide (H₂O₂). The limits of detection for the H₂O₂ were of the orders of ~10⁻⁷ M for all the modified electrodes. The modified electrodes gave very good analytical parameters; such as good sensitivity, linearity at studied concentration range and well-defined analytical peaks with increased current densities. The modification methods were reproducible, highly conducting thin films were formed and the modified electrodes were very stable. The design of electrochemical immunosensors for the detection of measles-specific antibodies was also carried out. The modified surface with measles-antigen as sensing element was accomplished using covalent immobilization for an intimate connection of the measles-antigen as a sensing layer onto an electrode surface. Two methods of detecting measles-specific antibodies were investigated and these methods were based on electrochemical impedance, i.e. label-free detection, and voltammetric method using horse-radish peroxidase (HRP) labeled antibody as a reporter. The detection of measles-specific antibodies was accomplished using both these methods. The potential applications of the designed immunosensor were evaluated in real samples (human and newborn calf serum) and the electrodes could detect the antibodies in the complex sample matrix with ease.
- Full Text:
- Date Issued: 2012
- Authors: Mashazi, Philani Nkosinathi
- Date: 2012
- Subjects: Phthalocyanines , Electrochemistry , Electrodes, Enzyme , Measles -- Measurement
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:5580 , http://hdl.handle.net/10962/d1018248
- Description: The synthesis of cobalt and manganese phthalocyanine complexes bearing eight hexylthio and four amino substituents was carried out. The formation of thin films of these complexes using different modification methods was also studied. Hexylthio functionalized metallophthalocyanine complexes were immobilized onto gold electrode surfaces using the self-assembly techniques. Surface modifications using cobalt and manganese tetraamino phthalocyanine as polymers, monolayers (onto electrografted surfaces) and as carbon nanotube – metallophthalocyanine conjugates was also carried out. The new method of modifying gold electrodes with metal tetraamino phthalocyanine complexes was investigated. The modified electrode surfaces were studied for their electrocatalytic properties and as potential electrochemical sensors for the detection of hydrogen peroxide (H₂O₂). The limits of detection for the H₂O₂ were of the orders of ~10⁻⁷ M for all the modified electrodes. The modified electrodes gave very good analytical parameters; such as good sensitivity, linearity at studied concentration range and well-defined analytical peaks with increased current densities. The modification methods were reproducible, highly conducting thin films were formed and the modified electrodes were very stable. The design of electrochemical immunosensors for the detection of measles-specific antibodies was also carried out. The modified surface with measles-antigen as sensing element was accomplished using covalent immobilization for an intimate connection of the measles-antigen as a sensing layer onto an electrode surface. Two methods of detecting measles-specific antibodies were investigated and these methods were based on electrochemical impedance, i.e. label-free detection, and voltammetric method using horse-radish peroxidase (HRP) labeled antibody as a reporter. The detection of measles-specific antibodies was accomplished using both these methods. The potential applications of the designed immunosensor were evaluated in real samples (human and newborn calf serum) and the electrodes could detect the antibodies in the complex sample matrix with ease.
- Full Text:
- Date Issued: 2012