Electropolymerized Fluorinated Aniline-Based Fiber for Headspace Solid-Phase Microextraction and Gas Chromatographic Determination of Benzaldehyde in Injectable Pharmaceutical Formulations
- Mohammadi, Ali, Mohammadi, Somayeh, Moghaddam, Bayandori A, Masoumi, Vahideh, Walker, Roderick B
- Authors: Mohammadi, Ali , Mohammadi, Somayeh , Moghaddam, Bayandori A , Masoumi, Vahideh , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184120 , vital:44175 , xlink:href="https://doi.org/10.1093/chromsci/bmt152"
- Description: In this study, a simple method was developed and validated to detect trace levels of benzaldehyde in injectable pharmaceutical formulations by solid-phase microextraction coupled with gas chromatography–flame ionization detector. Polyaniline was electrodeposited on a platinum wire in trifluoroacetic acid solvent by cyclic voltammetry technique. This fiber shows high thermal and mechanical stability and high performance in extraction of benzaldehyde. Extraction and desorption time and temperature, salt effect and gas chromatography parameters were optimized as key parameters. At the optimum conditions, the fiber shows good linearity between peak area ratio of benzaldehyde/3-chlorobenzaldehyde and benzaldehyde concentration in the range of 50–800 ng/mL with percent relative standard deviation values ranging from 0.75 to 8.64% (n 5 3). The limits of quantitation and detection were 50 and 16 ng/mL, respectively. The method has the requisite selectivity, sensitivity, accuracy and precision to assay benzaldehyde in injectable pharmaceutical dosage forms.
- Full Text:
- Date Issued: 2014
- Authors: Mohammadi, Ali , Mohammadi, Somayeh , Moghaddam, Bayandori A , Masoumi, Vahideh , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184120 , vital:44175 , xlink:href="https://doi.org/10.1093/chromsci/bmt152"
- Description: In this study, a simple method was developed and validated to detect trace levels of benzaldehyde in injectable pharmaceutical formulations by solid-phase microextraction coupled with gas chromatography–flame ionization detector. Polyaniline was electrodeposited on a platinum wire in trifluoroacetic acid solvent by cyclic voltammetry technique. This fiber shows high thermal and mechanical stability and high performance in extraction of benzaldehyde. Extraction and desorption time and temperature, salt effect and gas chromatography parameters were optimized as key parameters. At the optimum conditions, the fiber shows good linearity between peak area ratio of benzaldehyde/3-chlorobenzaldehyde and benzaldehyde concentration in the range of 50–800 ng/mL with percent relative standard deviation values ranging from 0.75 to 8.64% (n 5 3). The limits of quantitation and detection were 50 and 16 ng/mL, respectively. The method has the requisite selectivity, sensitivity, accuracy and precision to assay benzaldehyde in injectable pharmaceutical dosage forms.
- Full Text:
- Date Issued: 2014
Electro‐oxidation of acetaminophen on nickel/poly (o‐aminophenol)/multi‐walled carbon nanotube nanocomposite modified graphite electrode.
- Naeemy, Ali, Mohammadi, Ali, Bakhtiari, Hediech, Ashouri, Nasim, Walker, Roderick B
- Authors: Naeemy, Ali , Mohammadi, Ali , Bakhtiari, Hediech , Ashouri, Nasim , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184107 , vital:44173 , xlink:href="https://ietresearch.onlinelibrary.wiley.com/doi/pdf/10.1049/mnl.2014.0197"
- Description: Poly(o-aminophenol) (POAP)/multi-walled carbon nanotube (MWCNT) nanocomposite and POAP in the absence of the MWCNT were fabricated by consecutive cyclic voltammetry (CV) on a graphite (G) electrode. The dispersion of nickel (II) ions was accomplished and incorporated into the polymeric electrodes (G/POAP and G/POAP-MWCNT) by immersing them into a 0.1 M nickel (II) solution. Following preparation of G/POAP/Ni and G/POAP-MWCNT/Ni, the electrochemical behaviour was examined using CV. Scanning electron microscopy was used for characterisation of the nanocomposite. The prepared electrodes showed enhanced electrocatalytic activity for the oxidation of acetaminophen and facilitated the detection of acetaminophen in a 0.1 M NaOH solution. Compared with the G/POAP/Ni electrode, the G/POAP-MWCNT/Ni electrode had a significant current response of acetaminophen oxidation because of the synergistic effects of POAP and the MWCNT. By CV, the calibration plot was linear in the range of 1–13 mM with standard deviation between 0.3 and 6.54% for acetaminophen. The G/POAP-MWCNT/Ni was successfully applied for acetaminophen determination in tablets and the results showed sufficient precision and achieved a mean recovery of 96.8% (R.S.D. = 4.9%).
- Full Text:
- Date Issued: 2014
- Authors: Naeemy, Ali , Mohammadi, Ali , Bakhtiari, Hediech , Ashouri, Nasim , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184107 , vital:44173 , xlink:href="https://ietresearch.onlinelibrary.wiley.com/doi/pdf/10.1049/mnl.2014.0197"
- Description: Poly(o-aminophenol) (POAP)/multi-walled carbon nanotube (MWCNT) nanocomposite and POAP in the absence of the MWCNT were fabricated by consecutive cyclic voltammetry (CV) on a graphite (G) electrode. The dispersion of nickel (II) ions was accomplished and incorporated into the polymeric electrodes (G/POAP and G/POAP-MWCNT) by immersing them into a 0.1 M nickel (II) solution. Following preparation of G/POAP/Ni and G/POAP-MWCNT/Ni, the electrochemical behaviour was examined using CV. Scanning electron microscopy was used for characterisation of the nanocomposite. The prepared electrodes showed enhanced electrocatalytic activity for the oxidation of acetaminophen and facilitated the detection of acetaminophen in a 0.1 M NaOH solution. Compared with the G/POAP/Ni electrode, the G/POAP-MWCNT/Ni electrode had a significant current response of acetaminophen oxidation because of the synergistic effects of POAP and the MWCNT. By CV, the calibration plot was linear in the range of 1–13 mM with standard deviation between 0.3 and 6.54% for acetaminophen. The G/POAP-MWCNT/Ni was successfully applied for acetaminophen determination in tablets and the results showed sufficient precision and achieved a mean recovery of 96.8% (R.S.D. = 4.9%).
- Full Text:
- Date Issued: 2014
- «
- ‹