Drug transport mechanisms from carbopol/eudragit verapamil sustained-release tablets
- Khamanga, Sandile M, Walker, Roderick B
- Authors: Khamanga, Sandile M , Walker, Roderick B
- Date: 2011
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184801 , vital:44273 , xlink:href="https://doi.org/10.14227/dt180311p30"
- Description: The objectives of this study were to compare dissolution profiles of a verapamil (VRP) formulation manufactured inhouse and Isoptin SR using USP Apparatus 2 and 3 and to elucidate drug release kinetics of these dosage forms. Eudragit NE 30D (ethyl acrylate–methyl methacrylate copolymer in a 2:1 ratio) aqueous dispersion was used as a granulating binder for the manufacture of VRP mini-matrix sustained-release tablets. The wet granulation process was performed to prepare free-flowing granules that were blended with Carbopol. The tablets were manufactured using a single-punch press by compression of the granules with magnesium stearate as a lubricant. Drug release was determined in phosphate buffer solution using USP Apparatus 2 and 3. Dissolution data were fitted to zero- and first-order models; in addition, the kinetic data were determined by evaluation of Higuchi release kinetics. The mechanism of drug release was established using the Korsmeyer–Peppas model. In general, all tablets showed high mechanical resistance with less than 1% friability. There was no significant difference between the dissolution profiles of the formulation manufactured in-house and the commercially available product. The release mechanism of the formulated and marketed products was controlled by anomalous non-Fickian diffusion. VRP release was prolonged for 12 h indicating the usefulness of the formulation as a twice-daily dosage form. The mechanism of drug release for the dosage forms was unaffected by the choice of apparatus.
- Full Text:
- Date Issued: 2011
- Authors: Khamanga, Sandile M , Walker, Roderick B
- Date: 2011
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184801 , vital:44273 , xlink:href="https://doi.org/10.14227/dt180311p30"
- Description: The objectives of this study were to compare dissolution profiles of a verapamil (VRP) formulation manufactured inhouse and Isoptin SR using USP Apparatus 2 and 3 and to elucidate drug release kinetics of these dosage forms. Eudragit NE 30D (ethyl acrylate–methyl methacrylate copolymer in a 2:1 ratio) aqueous dispersion was used as a granulating binder for the manufacture of VRP mini-matrix sustained-release tablets. The wet granulation process was performed to prepare free-flowing granules that were blended with Carbopol. The tablets were manufactured using a single-punch press by compression of the granules with magnesium stearate as a lubricant. Drug release was determined in phosphate buffer solution using USP Apparatus 2 and 3. Dissolution data were fitted to zero- and first-order models; in addition, the kinetic data were determined by evaluation of Higuchi release kinetics. The mechanism of drug release was established using the Korsmeyer–Peppas model. In general, all tablets showed high mechanical resistance with less than 1% friability. There was no significant difference between the dissolution profiles of the formulation manufactured in-house and the commercially available product. The release mechanism of the formulated and marketed products was controlled by anomalous non-Fickian diffusion. VRP release was prolonged for 12 h indicating the usefulness of the formulation as a twice-daily dosage form. The mechanism of drug release for the dosage forms was unaffected by the choice of apparatus.
- Full Text:
- Date Issued: 2011
The use of experimental design in the development of an HPLC–ECD method for the analysis of captopril
- Khamanga, Sandile M, Walker, Roderick B
- Authors: Khamanga, Sandile M , Walker, Roderick B
- Date: 2011
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184056 , vital:44163 , xlink:href="https://doi.org/10.1016/j.talanta.2010.11.025"
- Description: An accurate, sensitive and specific high performance liquid chromatography–electrochemical detection (HPLC–ECD) method that was developed and validated for captopril (CPT) is presented. Separation was achieved using a Phenomenex® Luna 5 μm (C18) column and a mobile phase comprised of phosphate buffer (adjusted to pH 3.0): acetonitrile in a ratio of 70:30 (v/v). Detection was accomplished using a full scan multi channel ESA Coulometric detector in the “oxidative-screen” mode with the upstream electrode (E1) set at +600 mV and the downstream (analytical) electrode (E2) set at +950 mV, while the potential of the guard cell was maintained at +1050 mV. The detector gain was set at 300. Experimental design using central composite design (CCD) was used to facilitate method development. Mobile phase pH, molarity and concentration of acetonitrile (ACN) were considered the critical factors to be studied to establish the retention time of CPT and cyclizine (CYC) that was used as the internal standard. Twenty experiments including centre points were undertaken and a quadratic model was derived for the retention time for CPT using the experimental data. The method was validated for linearity, accuracy, precision, limits of quantitation and detection, as per the ICH guidelines. The system was found to produce sharp and well-resolved peaks for CPT and CYC with retention times of 3.08 and 7.56 min, respectively. Linear regression analysis for the calibration curve showed a good linear relationship with a regression coefficient of 0.978 in the concentration range of 2–70 μg/mL. The linear regression equation was y = 0.0131x + 0.0275. The limits of detection (LOQ) and quantitation (LOD) were found to be 2.27 and 0.6 μg/mL, respectively. The method was used to analyze CPT in tablets. The wide range for linearity, accuracy, sensitivity, short retention time and composition of the mobile phase indicated that this method is better for the quantification of CPT than the pharmacopoeial methods.
- Full Text:
- Date Issued: 2011
- Authors: Khamanga, Sandile M , Walker, Roderick B
- Date: 2011
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184056 , vital:44163 , xlink:href="https://doi.org/10.1016/j.talanta.2010.11.025"
- Description: An accurate, sensitive and specific high performance liquid chromatography–electrochemical detection (HPLC–ECD) method that was developed and validated for captopril (CPT) is presented. Separation was achieved using a Phenomenex® Luna 5 μm (C18) column and a mobile phase comprised of phosphate buffer (adjusted to pH 3.0): acetonitrile in a ratio of 70:30 (v/v). Detection was accomplished using a full scan multi channel ESA Coulometric detector in the “oxidative-screen” mode with the upstream electrode (E1) set at +600 mV and the downstream (analytical) electrode (E2) set at +950 mV, while the potential of the guard cell was maintained at +1050 mV. The detector gain was set at 300. Experimental design using central composite design (CCD) was used to facilitate method development. Mobile phase pH, molarity and concentration of acetonitrile (ACN) were considered the critical factors to be studied to establish the retention time of CPT and cyclizine (CYC) that was used as the internal standard. Twenty experiments including centre points were undertaken and a quadratic model was derived for the retention time for CPT using the experimental data. The method was validated for linearity, accuracy, precision, limits of quantitation and detection, as per the ICH guidelines. The system was found to produce sharp and well-resolved peaks for CPT and CYC with retention times of 3.08 and 7.56 min, respectively. Linear regression analysis for the calibration curve showed a good linear relationship with a regression coefficient of 0.978 in the concentration range of 2–70 μg/mL. The linear regression equation was y = 0.0131x + 0.0275. The limits of detection (LOQ) and quantitation (LOD) were found to be 2.27 and 0.6 μg/mL, respectively. The method was used to analyze CPT in tablets. The wide range for linearity, accuracy, sensitivity, short retention time and composition of the mobile phase indicated that this method is better for the quantification of CPT than the pharmacopoeial methods.
- Full Text:
- Date Issued: 2011
- «
- ‹
- 1
- ›
- »