Dynamics of charge movement in ∞-Al2O3:C,Mg using thermoluminescence phototransferred and optically stimulated luminescence
- Authors: Lontsi Sob, Aaron Joel
- Date: 2022-04-08
- Subjects: Thermoluminescence , Optically stimulated luminescence , Phototransfer , Deep traps , Phototransferred thermoluminescence (PTTL)
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/294607 , vital:57237 , DOI 10.21504/10962/294607
- Description: The dosimetric features of ∞-Al2O3:C,Mg have been investigated for unannealed and annealed samples. The unannealed sample is referred to as sample A whereas the samples annealed at 700, 900 and 1200°C for 15 minutes each are referred to as samples B, C and D respectively. A glow curve of unannealed ∞-Al2O3:C,Mg measured at 1°C/s after irradiation to 2.0 Gy consists of peaks at 43, 73, 164, 195, 246, 284, 336 and 374°C respectively. For sample B (annealed at 700°C), a glow curve measured at 1°C/s after irradiation to 3.0 Gy has peaks at 46, 76, 100, 170, 199, 290, 330 and 375°C whereas the glow curve of sample C (annealed at 900°C) recorded under the same conditions consists of peaks at 49, 80, 100, 174, 206, 235, 290, 335 and 375°C respectively. Sample D (annealed at 1200°C) is the most sensitive of the four samples. A glow curve of sample D measured at 1°C/s after irradiation to 0.2 Gy has peaks at 52, 82, 102, 174, 234, 288 and 384°C respectively. The peaks are labelled I-VIII in order of appearance. The 100°C peak, labelled IIa, is induced by annealing at or above 700°C. The dose response of these peaks was studied for doses within 0.1-8.2 Gy. The reported peaks follow first-order kinetics irrespective of annealing temperature. Peaks I-III of each sample are reproduced under phototransfer for preheating up to 400°C. For the unannealed sample, the reproduced peaks are labelled A1-A3 whereas for the annealed samples, they are labelled B1-B3, C1-C3 and D1-D3 respectively. The annealing-induced peak at 100°C is reproduced as B2a, C2a and D2a for samples B, C and D respectively. A PTTL peak labelled C2b or D2b is also observed near 140°C in samples C and D. In addition to these PTTL peaks, a PTTL peak corresponding to peak IV is also found for sample D and for the unannealed sample. As the corresponding conventional peaks, the PTTL peaks of each sample follow first-order kinetics. Peak I and its corresponding PTTL peak for each sample are unstable and fade to a minimal level after 300 s of storage time. On the other hand, peak II of each sample and its corresponding PTTL peak could still be observed with delay up to 5000 s. Peak III of the unannealed sample remains stable with storage time up to 48 hours. Irrespective of annealing, the trap corresponding to peak III is the most sensitive to optical stimulation. Time-dependent profiles of PTTL from unannealed and annealed ∞-Al2O3:C,Mg were also studied. The mathematical analysis of the PTTL time-response profiles is based on experimental results. The role of various electron traps in PTTL was determined by using pulse annealing and by monitoring the dependence of peak intensity on duration of illumination for peaks not removed by preheating. The presence and role of deep traps were further demonstrated with thermally assisted optically stimulated luminescence. For the unannealed sample, the activation energy for thermal assistance is 0.033 ± 0.001 eV and the activation energy for thermal i quenching is 1.043 ± 0.001 eV. For sample C, the activation energy for thermal assistance is 0.044 ± 0.003 eV whereas that for thermal quenching is 1.110 ± 0.006 eV. The values for the activation energy for thermal assistance are lower than those reported in literature. Only the values for the activation energy for thermal quenching are somewhat comparable to values reported elsewhere. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2022
- Full Text:
- Date Issued: 2022-04-08
Influence of argon ion implantation on the thermoluminescence properties of aluminium oxide
- Authors: Khabo, Bokang
- Date: 2022-04-06
- Subjects: Aluminum oxide , Thermoluminescence , Ion implantation , Kinetic analysis , Oxygen vacancies , Argon , Irradiation
- Language: English
- Type: Master's thesis , text
- Identifier: http://hdl.handle.net/10962/234220 , vital:50173
- Description: The influence of argon ion implantation on the thermoluminescence properties (TL) of aluminium oxide (alumina) was investigated. Aluminium oxide (Al2O3) samples were implanted with 80 keV Ar ions. An unimplanted sample and samples implanted at fluences of 1×1014, 5×1014, 1×1015, 5×1015, 1×1016 Ar+/cm2 were irradiated at a dose of 40 Gy and heated at a rate of 1°C/s using a Risø reader model TL/OSL-DA-20 equipped with a Hoya U-340 filter. The thermoluminescence glow curves showed five distinct peaks with main peaks at 178°C, 188°C, 176°C, 208°C, 216°C and 204°C for the unimplanted sample as well as implanted samples. The peak positions of the samples were independent of the irradiation dose suggesting that the samples were characterised by first order kinetics. This was also confirmed by the TM-TSTOP analysis. It was observed that the TL intensity decreases with fluence of implantation. This observation suggests that the concentration of electron traps responsible for thermoluminescence decreases with ion implantation. The decrease in electron concentration might be due to the formation of non-radiative transition bands or the creation of defect clusters and extended defects following the ion implantation and ion fluence increases. The stopping and range of atoms in matter (SRIM) program was used to correlate the TL response of Al2O3 with defects under ion implantation. Subsequent to ion implantation, it was found that the number of oxygen vacancies which are related to electron traps are higher than the number of aluminium vacancies. Kinetic analysis was carried out using the initial rise, Chens peak shape, various heating rate, the whole glow curve, glow curve fitting and the isothermal decay methods. The activation energy was found to be around 0.8 eV and the frequency factor to be of the order 108 𝑠−1 regardless of the implantation fluence. This means that argon ion implantation did not affect the nature of electron traps. The dosimetric features of samples were also investigated at doses in the range of 40 – 200 Gy. Samples generally showed a superlinear response at doses less than 140 Gy and sublinear response at doses higher than 160 Gy. , Thesis (MSc) -- Faculty of Science, Physics and Electronics, 2022
- Full Text:
- Date Issued: 2022-04-06
Dynamics of stimulated luminescence in natural quartz: Thermoluminescence and phototransferred thermoluminescence
- Authors: Folley, Damilola Esther
- Date: 2020
- Subjects: Thermoluminescence , Quartz
- Language: English
- Type: text , Thesis , Doctoral , PhD
- Identifier: http://hdl.handle.net/10962/146255 , vital:38509
- Description: Natural quartz has remained an important mineral that is of topical interest in luminescence and dosimetry-related research. We investigate the dynamics of stimulated luminescence on this material through thermoluminescence (TL) and phototransferred thermoluminescence (PTTL). Measurements were made on unannealed natural quartz as well as quartz annealed at 800 and 1000̊C. The samples were annealed for 10 minutes and for 1 hour. The material, in its un- and annealed state has its main peak between 68 and 72̊C when measured at 1Cs ̃1 after a dose of 50 Gy. A study of dosimetric features and kinetic analysis was carried out on two prominent peaks, peak I and III for all the samples. The peaks show a sublinear dose response for irradiation doses between 10 and 300 Gy. Kinetic analysis shows that peak I is a first-order peak and peak III a general-order peak. Interestingly, we observe for peak I for the sample annealed at 800̊C for 1 hour an inverse thermal quenching behaviour. We demonstrate that a peak affected with an inverse thermal quenching-like behaviour can still show effect of thermal quenching when the dose the sample is irradiated to is significantly reduced. We ascribe the apparent dependence of thermal quenching on dose to competition between radiative and non-radiative transitions at the recombination centre. Peaks I, II, and III for all the samples were reproduced under phototransfer when the peaks, initially removed by preheating to a certain temperature are exposed to 470 and 525 nm light. The infuence of duration of illumination on the PTTL intensity of these peaks corresponding to various preheating temperatures is modelled using coupled first-order dfferential equations. The model is based on systems of acceptors and donors whose number and role depends on preheating temperature
- Full Text:
- Date Issued: 2020
Thermoluminescence and phototransferred phermoluminescence of synthetic quartz
- Authors: Dawam, Robert Rangmou
- Date: 2020
- Subjects: Thermoluminescence , Quartz
- Language: English
- Type: text , Thesis , Doctoral , PhD
- Identifier: http://hdl.handle.net/10962/145849 , vital:38472
- Description: The main aim of this investigation is on thermoluminescence and phototransferred thermoluminescence of synthetic quartz. Thermoluminescence was one of the tools used in characterising the electron traps parameters. The samples of quartz annealed at various temperatures up to 900̊C and the unannealed were used. The thermoluminescence glow curve was measured at 1̊C s~ 1 following beta irradiation to 40 Gy from the samples annealed at 500̊C and the unannealed consist of main peak at 70̊C and secondary peaks at 110, 180 and 310̊C. In comparison, the thermoluminescence glow curve for the sample annealed at 900̊C have main peak at 86̊C and the secondary ones at 170 and 310̊C. The kinetic analysis was carried out only on the main peak in each case. The activation energy was found to be decreasing with increase in annealing temperatures. The samples annealed at 500̊C and the unannealed were found to be affected by thermal quenching while sample annealed at 900̊C shows an inverse quenching for irradiation dose of 40 Gy. However, when the dose was reduce to 3 Gy the effects of thermal quenching was manifested. The activation energy of thermal quenching was also found to decrease with increase in annealing temperature. Thermally assisted optically stimulated luminescence measurement was carried out using continuous wave optical stimulated luminescence (CW-OSL). The samples studied were those annealed at 500̊C for 10 minutes, 900̊C for 10, 30, 60 minutes and 1000̊C for 10 minutes prior to use. The CW-OSL is stimulated using 470 nm blue LEDs at sample temperatures between 30 and 200̊C. It is measured after preheating to either 300 and 500̊C. When the integrated OSL intensity is plotted as a function of measurement temperature, the intensity goes through a peak. The increase in OSL intensity as a function of temperature is associated to thermal assistance and the decrease to thermal quenching. The kinetic parameters were evaluated by fitting the experimental data. The values of activation energies of thermal quenching are the same within experimental uncertainties for all the experimental conditions. This shows that annealing temperature, duration of annealing and irradiation dose have a negligible influence on the recombination site of luminescence using OSL. Phototransferred thermoluminescence (PTTL) induced from annealed samples using 470 nm blue light was also investigated. The quartz were annealed at 500 _C for 10 minutes, 900̊C for 10, 30, 60 minutes and 1000̊C for 10 minutes prior to use. The glow curves of conventional TL measured at 1 _C s1 following irradiation to 200 Gy shows six peaks in each case labelled I-VI for ease of reference whereas peaks observed under PTTL are referred to as A1 onwards. Only the first three peaks were reproduced under phototransfer for the sample annealed at 900̊C for 60 minutes and 1000̊C C for 10 minutes. Interestingly, for the intermediate duration of annealing of 30 minutes, the only peak that appears under phototransfer is the A1. For quartz annealed at 900̊C for 10 minutes, the PTTL appears as long as the preheating temperature does not exceed 560̊C. All other annealing temperatures, PTTL only appears for preheating to 450 and below. This shows that the occupancy of deep electron traps at temperatures beyond 450̊C or 560̊C is low. The activation energy for peaks A1, A2 and A3 were calculated. The PTTL peaks were studied for thermal quenching and peaks A1 and A3 were found to be affected. The activation energies for thermal quenching were determined as 0.62 ± 0.04 eV and 0.65 ± 0.02 eV for peaks A1 and A3 respectively. The experimental dependence of PTTL intensity on illumination time is modelled using sets of coupled linear differential equations based on systems of donors and acceptors whose number is determined by preheating temperature.
- Full Text:
- Date Issued: 2020
Combined spectral and stimulated luminescence study of charge trapping and recombination processes in α-Al2O3:C
- Authors: Nyirenda, Angel Newton
- Date: 2018
- Subjects: Luminescence , Thermoluminescence , Luminescence spectroscopy , Carbon-doped aluminium oxide , Radioluminescence , Time-resolved X-ray excited optical luminescence
- Language: English
- Type: text , Thesis , Doctoral , PhD
- Identifier: http://hdl.handle.net/10962/62683 , vital:28235
- Description: The main objective of this project was to gain a deeper and better understanding of the luminescence processes in a-Al₂O₃:C, a highly-sensitive dosimetric material, using a combined spectral and stimulated luminescence study. The spectral studies concentrated on the emission spectra obtained using X-ray induced radioluminescence (XERL), thermoluminescence (XETL) and time-resolved X-ray excited optical luminescence (TR-XEOL) techniques. The stimulated luminescence studies were based on thermoluminescence (TL), optically stimulated luminescence (OSL) and phototransferred TL (PTTL) methods that were used in the study of the radiation-induced defects at high beta-doses and the deep traps, that is, traps with thermal depths beyond 500°C. The spectral and stimulated luminescence measurements were carried out using a high sensitivity luminescence spectrometer and a Ris0 TL/OSL Model DA-20 Reader, respectively. The XERL emission spectrum measured at room temperature shows seven gaussian peaks associated with F-centres (420 nm), F+-centres (334 nm), F2+-centres (559 nm), Stoke’s vibronic band of Cr3+ (671 nm), Cr3+ R-line emission (694 nm), anti-Stokes vibronic band of Cr3+ (710 nm) and an unidentified emission band (260-300 nm) which we associate with hole recombinations at a luminescence centre. The 694-nm R-line emission from Cr3+ impurity ions is most likely due to recombination of holes at Cr2+ during stimulated luminescence and as a result of an intracentre excitation of Cr3+ in photoluminescence (PL) due to photon absorption. The Cr3+ emission decreases in intensity, whereas the intensity of F-centre emission band is almost constant with repeated XERL measurements. Depending on the amount of X-ray irradiation dose, both holes and/or electrons may take place in the emission processes of peaks I (30-80°C), II (90-250°C) and III (250-320°C) during a TL readout, albeit, electron recombination is dominant regardless of dose. At higher doses, the XETL emission spectra indicate that the dominant band associated with TL peak III (250-320°C) in the material, shifts from F-centre to Cr3+. Using the deep-traps OSL, it has been confirmed that the main TL trap is also the main OSL trap whereas the TL traps lying in the temperature range of 400-550°C constitute the secondary OSL traps. There is evidence of strong retrapping at the main trap during optical stimulation of charges from the secondary OSL traps and the deep traps and that the retrapping occurs via the delocalized bands. At high-irradiation beta-doses, aggregate defect centres which significantly alter the TL and OSL properties, are induced in the material. The induced aggregate centres get completely obliterated by heating a sample to 700°C. The radiation-induced defects cause the main TL peak to shift towards higher temperatures, increase its FWHM, reduce its maximum intensity and cause an underestimation of both the activation energy and order of kinetics of the peak. On the other hand, the OSL response of the material is enhanced following a high-irradiation dose. During sample storage in the dark at ambient temperature, charges do migrate from the deep traps (donors) to the main and intermediate traps (acceptors) and that the major donor traps during this charge transfer phenomenon lie between 500-600°C.
- Full Text:
- Date Issued: 2018
Thermoluminescence characteristics of synthetic quartz
- Authors: Niyonzima, Pontien
- Date: 2014
- Subjects: Thermoluminescence , Quartz , Emission spectroscopy
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:5538 , http://hdl.handle.net/10962/d1013190
- Description: Quartz is one of the most abundant natural minerals in the crust of the earth. Due to its dosimetric luminescence properties, it is employed in retrospective dosimetry, archaeological and geological dating. The intensity and the structure of the TL glow curves of quartz are strongly dependent upon the origin, impurity content, formation condition and pre-irradiation heat treatment. The aim of this project is to study the mechanisms of thermoluminescence (TL), Phototranssferred thermoluminescence (PTTL) and radioluminescence (RL) in synthetic quartz and to discuss the results in terms of physical characteristics of point defects involved. Thermoluminescence measurements were made on a sample of synthetic quartz in its as-received state (unannealed) synthetic quartz annealed at 500˚C for 10 minutes. The unannealed sample shows six TL glow peaks located at 94, 116, 176, 212, 280 and 348˚C at a heating rate of 5˚Cs⁻¹. The annealed sample shows seven TL peaks at 115, 148, 214, 246, 300, 348 and 412˚C at a heating rate of 5˚Cs⁻¹. The intensity of peak I, at 94 and 115˚C for the unannealed and annealed samples respectively, increases with irradiation. Peak I has an activation energy of approximately 0.90 eV and a frequency factor of the order of 10¹¹ s⁻¹. The order of kinetics is between 0.9 and 1.2. The unannealed synthetic quartz shows phototransferred thermoluminescence (PTTL) at the position of peak I after removal of the first three peaks followed by illumination. The PTTL intensities show peak shaped behaviour when plotted against illumination time. The PTTL showed a quadratic increase with dose. The material exhibits fading of PTTL intensity with delay time. Radioluminescence was measured on synthetic quartz unannealed and annealed annealed at 500, 600, 700, 800, 900 and 1000˚C for 10 to 60 min. The emission spectra of synthetic quartz show seven emission bands. The effect of irradiation on the RL spectra is to increase the intensity of all emission bands for samples annealed at temperatures less than or equal to 700˚C. The effect of annealing time is to increase the RL amplitude for the samples annealed at temperatures greater than 700˚C. The annealing temperature increases the RL amplitude of all emission bands of the spectrum for all samples.
- Full Text:
- Date Issued: 2014
Thermoluminescence of natural quartz
- Authors: Lontsi Sob, Aaron Joel
- Date: 2014
- Subjects: Thermoluminescence , Quartz , Thermoluminescence dosimetry
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:5543 , http://hdl.handle.net/10962/d1013358
- Description: The kinetic and dosimetric features of the main thermoluminescence peak of quartz have been investigated in unannealed as well in quartz annealed at 500˚C for 10 minutes. The main peak is found at 92 and 86˚C respectively for aliquots of unannealed and annealed samples irradiated to 10 Gy and heated at 5.0˚C/s. For each sample, the intensity of the main peak is enhanced with repetitive measurement whereas its maximum temperature is unaffected. The peak position of the main peak in each sample is independent of the irradiation dose and this, together with its fading characteristics are consistent with first-order kinetics. For low doses, typically between 2 and 10 Gy, the dose response of the main peak in each sample is linear. In the intermediate dose range from 10 to 60 Gy, the growth of the main peak in each sample is sub-linear and for greater doses, in the range from 60 Gy to 151 Gy, it is linear again. The half-life of the main peak of the unannealed sample is about 1.3 h whereas that of the annealed sample is about 1.2 h. The main peak in each sample can be approximated to a first-order glow peak. As the heating rate increases, the intensity of the main peak in each sample decreases. This is evidence of thermal quenching. The main peak in each sample is the only peak regenerated by phototransfer. The resulting phototransferred peak occurs at the same temperature as the original peak and has similar kinetic and dosimetric features. For a preheat temperature of 120˚C, the intensity of the phototransferred peak in each sample increases with illumination time up to a maximum and decreases afterwards. At longer illumination times (such as 30 min up to 1 h), no further decrease in the intensity of the phototransferred peak is observed. The traps associated with the 325˚C peak are the main source of the electrons responsible for the regenerated peak. Radioluminescence emission spectra were also measured for quartz annealed at various temperatures. Emission bands in quartz are affected by annealing and irradiation. A strong enhancement of the 3.4 eV (~366 nm) emission band is observed in quartz annealed at 500˚C. A new emission band which grows with annealing up to 1000˚C is observed at 3.7 eV (~330 nm) for quartz annealed at 600˚C. An attempt has been made to correlate the changes in radioluminescence emission spectra due to annealing with the influence of annealing on luminescence lifetimes in quartz.
- Full Text:
- Date Issued: 2014
Thermoluminescence of secondary glow peaks in carbon-doped aluminium oxide
- Authors: Seneza, Cleophace
- Date: 2014
- Subjects: Thermoluminescence , Aluminum oxide , Thermoluminescence dosimetry
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:5537 , http://hdl.handle.net/10962/d1013053
- Description: Carbon-doped aluminium oxide, α-Al₂O₃ : C, is a highly sensitive luminescence dosimeter. The high sensitivity of α-Al₂O₃ : C has been attributed to large concentrations of oxygen vacancies, F and F⁺ centres, induced in the material during its preparation. The material is prepared in a highly reducing atmosphere in the presence of carbon. In the luminescence process, electrons are trapped in F-centre defects as a result of irradiation of the material. Thermal or optical release of trapped electrons leads to emission of light, thermoluminescence (TL) or optically stimulated light (OSL) respectively. The thermoluminescence technique is used to study point defects involved in luminescence of α-Al₂O₃ : C. A glow curve of α-Al₂O₃ : C, generally, shows three peaks; the main dosimetric peak of high intensity (peak II) and two other peaks of lower intensity called secondary glow peaks (peaks I and III). The overall aim of our work was to study the TL mechanisms responsible for secondary glow peaks in α-Al₂O₃ : C. The dynamics of charge movement between centres during the TL process was studied. The phototransferred thermoluminescence (PTTL) from secondary glow peaks was also studied. The kinetic analysis of TL from secondary peaks has shown that the activation energy of peak I is 0.7 eV and that of peak III, 1.2 eV. The frequency factor, the frequency at which an electron attempts to escape a trap, was found near the range of the Debye vibration frequency. Values of the activation energy are consistent within a variety of methods used. The two peaks follow first order kinetics as confirmed by the TM-Tstop method. A linear dependence of TL from peak I on dose is observed at various doses from 0.5 to 2.5 Gy. The peak position for peak I was also independent on dose, further confirmation that peak I is of first order kinetics. Peak I suffers from thermal fading with storage with a half-life of about 120 s. The dependence of TL intensity for peak I increased as a function of heating rate from 0.2 to 6ºCs⁻¹. In contrast to the TL intensity for peak I, the intensity of TL for peak III decreases with an increase of heating rate from 0.2 to 6ºCs⁻¹. This is evidence of thermal quenching for peak III. Parameters W = 1.48 ± 0:10 eV and C = 4 x 10¹³ of thermal quenching were calculated from peak III intensities at different heating rates. Thermal cleaning of peak III and the glow curve deconvolution methods confirmed that the main peak is actually overlapped by a small peak (labeled peak IIA). The kinetic analysis of peak IIA showed that it is of first order kinetics and that its activation energy is 1:0 eV. In addition, the peak IIA is affected by thermal quenching. Another secondary peak appears at 422ºC (peak IV). However, the kinetic analysis of TL from peak IV was not studied because its intensity is not well defined. A heating rate of 0.4ºCs⁻¹ was used after a dose of 3 Gy in kinetic analysis of peaks IIA and III. The study of the PTTL showed that peaks I and II were regenerated under PTTL but peak III was not. Various effects of the PTTL for peaks I and II for different preheating temperatures in different samples were observed. The effect of annealing at 900ºC for 15 minutes between measurements following each illumination time was studied. The effect of dose on secondary peaks was also studied in this work. The kinetic analysis of the PTTL intensity for peak I showed that its activation energy is 0.7 eV, consistent with the activation energy of the normal TL for peak I. The PTTL intensity from peak I fades rapidly with storage compared with the thermal fading from peak I of the normal TL. The PTTL intensity for peak I decreases as a function of heating rate. This decrease was attributed to thermal quenching. Thermal quenching was not observed in the case of the normal TL intensity. The cause of this contrast requires further study.
- Full Text:
- Date Issued: 2014