Assessment of the prevalence of faecal coliforms and Escherichia coli o157:h7 in the final effluents of two wastewater treatment plants in Amahlathi Local Municipality of Eastern Cape Province, South Africa
- Authors: Ajibade, Adefisoye Martins
- Date: 2014
- Subjects: Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11283 , http://hdl.handle.net/10353/d1016166 , Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Description: The production of final effluents that meet discharged requirements and guidelines remain a major challenge particularly in the developing world with the resultant problem of surface water pollution. This study assessed the physicochemical and microbiological qualities of two wastewater treatment works in the Eastern Cape Province of South Africa in terms of the prevalence of faecal coliforms and Escherichia coli O157:H7 over a five month period. All physicochemical and microbiological analyses were carried out using standard methods. Data were collected in triplicates and analysed statistically using IBM SPSS version 20.0. The ranges of some of the physicochemical parameters that complied with set guidelines include pH (6.7 – 7.6), TDS (107 – 171 mg/L), EC (168 – 266 μS/cm), Temperature (15 – 24oC), NO3- (0 – 8.2 mg/L), NO2- (0.14 – 0.71 mg/L) and PO4 (1.05 – 4.50 mg/L). Others including Turbidity (2.64 – 58.00 NTU), Free Cl (0.13 – 0.65 mg/L), DO (2.20 – 8.48 mg/L), BOD (0.13 – 6.85 mg/L) and COD (40 – 482 mg/L) did not comply with set guidelines. The microbiological parameters ranged 0 – 2.7 × 104 CFU/100 ml for FC and 0 – 9.3 × 103 for EHEC CFU/100 ml, an indication of non-compliance with set guidelines. Preliminary identification of 40 randomly selected presumptive enterohemorrhagic E. coli isolates by Gram’s staining and oxidase test shows 100% (all 40 selected isolates) to be Gram positive while 90% (36 randomly selected isolates) were oxidase negative. Statistical correlation between the physicochemical and the microbiological parameters were generally weak except in the case of free chlorine and DO where they showed inverse correlation with the microbiological parameters. The recovery of EHEC showed the inefficiency of the treatment processes to effectively inactivate the bacteria, and possibly other pathogenic bacteria that may be present in the treated wastewater. The assessment suggested the need for proper monitoring and a review of the treatment procedures used at these treatment works.
- Full Text:
- Date Issued: 2014
- Authors: Ajibade, Adefisoye Martins
- Date: 2014
- Subjects: Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11283 , http://hdl.handle.net/10353/d1016166 , Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Description: The production of final effluents that meet discharged requirements and guidelines remain a major challenge particularly in the developing world with the resultant problem of surface water pollution. This study assessed the physicochemical and microbiological qualities of two wastewater treatment works in the Eastern Cape Province of South Africa in terms of the prevalence of faecal coliforms and Escherichia coli O157:H7 over a five month period. All physicochemical and microbiological analyses were carried out using standard methods. Data were collected in triplicates and analysed statistically using IBM SPSS version 20.0. The ranges of some of the physicochemical parameters that complied with set guidelines include pH (6.7 – 7.6), TDS (107 – 171 mg/L), EC (168 – 266 μS/cm), Temperature (15 – 24oC), NO3- (0 – 8.2 mg/L), NO2- (0.14 – 0.71 mg/L) and PO4 (1.05 – 4.50 mg/L). Others including Turbidity (2.64 – 58.00 NTU), Free Cl (0.13 – 0.65 mg/L), DO (2.20 – 8.48 mg/L), BOD (0.13 – 6.85 mg/L) and COD (40 – 482 mg/L) did not comply with set guidelines. The microbiological parameters ranged 0 – 2.7 × 104 CFU/100 ml for FC and 0 – 9.3 × 103 for EHEC CFU/100 ml, an indication of non-compliance with set guidelines. Preliminary identification of 40 randomly selected presumptive enterohemorrhagic E. coli isolates by Gram’s staining and oxidase test shows 100% (all 40 selected isolates) to be Gram positive while 90% (36 randomly selected isolates) were oxidase negative. Statistical correlation between the physicochemical and the microbiological parameters were generally weak except in the case of free chlorine and DO where they showed inverse correlation with the microbiological parameters. The recovery of EHEC showed the inefficiency of the treatment processes to effectively inactivate the bacteria, and possibly other pathogenic bacteria that may be present in the treated wastewater. The assessment suggested the need for proper monitoring and a review of the treatment procedures used at these treatment works.
- Full Text:
- Date Issued: 2014
Evaluation of some wastewater treatment facilities in Chris Hani and Amathole district municipalities as potential sources of Escherichia coli in the environment
- Authors: Mazwi, Sinazo Nomathamsanqa
- Date: 2014
- Subjects: Escherichia coli -- South Africa -- Eastern Cape , Water -- Purification
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11285 , http://hdl.handle.net/10353/d1019804 , Escherichia coli -- South Africa -- Eastern Cape , Water -- Purification
- Description: Access to clean and safe water is essential for the survival of human beings. Pollution of freshwater sources constitutes a major problem hindering access to safe water for drinking and other domestic uses. Wastewater effluent discharges often impact the microbiological qualities of surface waters with its attendant health and environmental problems. This study evaluated the microbiological qualities of the discharged effluents of four selected wastewater treatment plants in Amathole and Chris Hani District Municipalities of the Eastern Cape Province over a twelve-month sampling period. Microbiological analysis (faecal coliform, Escherichia coli and Escherichia coli O157:H7) was done using standard methods and polymerase chain reaction method was used to confirm identities ofbacterial isolates. Presumptive bacteria counts ranged as follows: faecal coliforms 0 to 1.6 × 103 CFU/100 ml, E. coli 0 to 1.4 × 103 CFU/100 ml and E. coli O157:H7 0 to 9.6 × 102 CFU/100 ml. Forty eight percent (305/626) of the presumptive E. coli isolates were confirmed using species-specific uidA gene which code for β-glucuronidase enzyme in E. coli. Antibiotic susceptibility profile of the isolate using a panel of 10 antibiotics shows 100% (150/150) resistance to antibiotics rifampicin and penicillin G while 49.3% (74/150) of the isolates and 46.7% (70/150) were susceptible to streptomycin and cefotaxime respectively. Multiple antibiotic resistance phenotypes (MARP) of the isolates showed resistance to two or more test antibiotics while the calculated multiple antibiotic resistance index (MARI) for the tested isolated is 0.49. The detection of potentially pathogenic E. coli in the final effluents suggestspotential danger to the receiving water bodies where the effluents are discharge. The high MARI valued obtained in this study indicates that the isolates are form environment where the tested antibiotics are being used and may further lead to the spread of multiple antibiotics resistance among other pathogens that may be present in the same environment.
- Full Text:
- Date Issued: 2014
- Authors: Mazwi, Sinazo Nomathamsanqa
- Date: 2014
- Subjects: Escherichia coli -- South Africa -- Eastern Cape , Water -- Purification
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11285 , http://hdl.handle.net/10353/d1019804 , Escherichia coli -- South Africa -- Eastern Cape , Water -- Purification
- Description: Access to clean and safe water is essential for the survival of human beings. Pollution of freshwater sources constitutes a major problem hindering access to safe water for drinking and other domestic uses. Wastewater effluent discharges often impact the microbiological qualities of surface waters with its attendant health and environmental problems. This study evaluated the microbiological qualities of the discharged effluents of four selected wastewater treatment plants in Amathole and Chris Hani District Municipalities of the Eastern Cape Province over a twelve-month sampling period. Microbiological analysis (faecal coliform, Escherichia coli and Escherichia coli O157:H7) was done using standard methods and polymerase chain reaction method was used to confirm identities ofbacterial isolates. Presumptive bacteria counts ranged as follows: faecal coliforms 0 to 1.6 × 103 CFU/100 ml, E. coli 0 to 1.4 × 103 CFU/100 ml and E. coli O157:H7 0 to 9.6 × 102 CFU/100 ml. Forty eight percent (305/626) of the presumptive E. coli isolates were confirmed using species-specific uidA gene which code for β-glucuronidase enzyme in E. coli. Antibiotic susceptibility profile of the isolate using a panel of 10 antibiotics shows 100% (150/150) resistance to antibiotics rifampicin and penicillin G while 49.3% (74/150) of the isolates and 46.7% (70/150) were susceptible to streptomycin and cefotaxime respectively. Multiple antibiotic resistance phenotypes (MARP) of the isolates showed resistance to two or more test antibiotics while the calculated multiple antibiotic resistance index (MARI) for the tested isolated is 0.49. The detection of potentially pathogenic E. coli in the final effluents suggestspotential danger to the receiving water bodies where the effluents are discharge. The high MARI valued obtained in this study indicates that the isolates are form environment where the tested antibiotics are being used and may further lead to the spread of multiple antibiotics resistance among other pathogens that may be present in the same environment.
- Full Text:
- Date Issued: 2014
The water and nutrient potential of brewery effluent for hydroponic tomato production
- Authors: Power, Sean Duncan
- Date: 2014
- Subjects: Hydroponics , Tomatoes -- Breeding , Brewery waste , Water -- Purification , Algae culture , Algae -- Biotechnology , Nitric acid , Phosphoric acid
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:5358 , http://hdl.handle.net/10962/d1011604 , Hydroponics , Tomatoes -- Breeding , Brewery waste , Water -- Purification , Algae culture , Algae -- Biotechnology , Nitric acid , Phosphoric acid
- Description: Brewery effluent that had undergone treatment in an anaerobic digester (AD) was used as an alternative water and nutrient source for hydroponic crop production. Brewery effluent was demonstrated to contain sufficient nutrients to support the growth, flowering and fruiting of Lycopersicum escolentum "Moneymaker" tomato crops. The adjustment of the effluent pH with phosphoric acid to between pH 6.0 and 6.5 increased the development of the crops by around 100% compared to crops grown in unaltered effluent. The pH adjusted effluent-grown plants grew to a mean height of 831.4 ± 21.1 mm and a dry biomass weight of 42.34 ± 2.76 g compared to the unaltered pH effluent plants which grew to a height of 410.6 ± 20.5 mm and a weight of 7.65 ± 0.68 g after 49 days. Effluent treatment in high-rate algal ponds (HRAP) was determined to have no positive effect on the nutritional potential of the effluent for Moneymaker production. The effluent-grown plants did not perform as well as plants grown in inorganic-fertilizer and municipal water. Plants grown in effluent grew taller but did not produce significantly more fruit when phosphoric acid (height: 1573.3 ± 50.4 mm, 19.4 ± 1.4 fruit per plant) was compared to nitric acid (height: 1254.1 ± 25.4 mm, 15.6 ± 1.5 fruit per plant) as the pH adjustment over 72 days. Direct and secondary plant stresses from effluent alkalinity, ammonium nutrition, nitrogen limitation, sodium concentrations and heat stress among other factors were probably confounding variables in these trials and require further investigation. Considering the raw effluent composition and manipulating the AD operation is a potential opportunity to improve overall AD performance, reduce chemical inputs in the effluent treatment process, reduce the final effluent alkalinity, and increase available nitrogen content in the final effluent. The anaerobic digester discharging >1000 m³ of nutrient enriched effluent every day is a resource with considerable potential. The benefits of developing this resource can contribute to cost-reduction at the brewery, more efficient water, nutrient and energy management at the brewery, and offer opportunities for job creation and potentially benefit local food security.
- Full Text:
- Date Issued: 2014
- Authors: Power, Sean Duncan
- Date: 2014
- Subjects: Hydroponics , Tomatoes -- Breeding , Brewery waste , Water -- Purification , Algae culture , Algae -- Biotechnology , Nitric acid , Phosphoric acid
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:5358 , http://hdl.handle.net/10962/d1011604 , Hydroponics , Tomatoes -- Breeding , Brewery waste , Water -- Purification , Algae culture , Algae -- Biotechnology , Nitric acid , Phosphoric acid
- Description: Brewery effluent that had undergone treatment in an anaerobic digester (AD) was used as an alternative water and nutrient source for hydroponic crop production. Brewery effluent was demonstrated to contain sufficient nutrients to support the growth, flowering and fruiting of Lycopersicum escolentum "Moneymaker" tomato crops. The adjustment of the effluent pH with phosphoric acid to between pH 6.0 and 6.5 increased the development of the crops by around 100% compared to crops grown in unaltered effluent. The pH adjusted effluent-grown plants grew to a mean height of 831.4 ± 21.1 mm and a dry biomass weight of 42.34 ± 2.76 g compared to the unaltered pH effluent plants which grew to a height of 410.6 ± 20.5 mm and a weight of 7.65 ± 0.68 g after 49 days. Effluent treatment in high-rate algal ponds (HRAP) was determined to have no positive effect on the nutritional potential of the effluent for Moneymaker production. The effluent-grown plants did not perform as well as plants grown in inorganic-fertilizer and municipal water. Plants grown in effluent grew taller but did not produce significantly more fruit when phosphoric acid (height: 1573.3 ± 50.4 mm, 19.4 ± 1.4 fruit per plant) was compared to nitric acid (height: 1254.1 ± 25.4 mm, 15.6 ± 1.5 fruit per plant) as the pH adjustment over 72 days. Direct and secondary plant stresses from effluent alkalinity, ammonium nutrition, nitrogen limitation, sodium concentrations and heat stress among other factors were probably confounding variables in these trials and require further investigation. Considering the raw effluent composition and manipulating the AD operation is a potential opportunity to improve overall AD performance, reduce chemical inputs in the effluent treatment process, reduce the final effluent alkalinity, and increase available nitrogen content in the final effluent. The anaerobic digester discharging >1000 m³ of nutrient enriched effluent every day is a resource with considerable potential. The benefits of developing this resource can contribute to cost-reduction at the brewery, more efficient water, nutrient and energy management at the brewery, and offer opportunities for job creation and potentially benefit local food security.
- Full Text:
- Date Issued: 2014
- «
- ‹
- 1
- ›
- »