Assessment of the prevalence of faecal coliforms and Escherichia coli o157:h7 in the final effluents of two wastewater treatment plants in Amahlathi Local Municipality of Eastern Cape Province, South Africa
- Authors: Ajibade, Adefisoye Martins
- Date: 2014
- Subjects: Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11283 , http://hdl.handle.net/10353/d1016166 , Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Description: The production of final effluents that meet discharged requirements and guidelines remain a major challenge particularly in the developing world with the resultant problem of surface water pollution. This study assessed the physicochemical and microbiological qualities of two wastewater treatment works in the Eastern Cape Province of South Africa in terms of the prevalence of faecal coliforms and Escherichia coli O157:H7 over a five month period. All physicochemical and microbiological analyses were carried out using standard methods. Data were collected in triplicates and analysed statistically using IBM SPSS version 20.0. The ranges of some of the physicochemical parameters that complied with set guidelines include pH (6.7 – 7.6), TDS (107 – 171 mg/L), EC (168 – 266 μS/cm), Temperature (15 – 24oC), NO3- (0 – 8.2 mg/L), NO2- (0.14 – 0.71 mg/L) and PO4 (1.05 – 4.50 mg/L). Others including Turbidity (2.64 – 58.00 NTU), Free Cl (0.13 – 0.65 mg/L), DO (2.20 – 8.48 mg/L), BOD (0.13 – 6.85 mg/L) and COD (40 – 482 mg/L) did not comply with set guidelines. The microbiological parameters ranged 0 – 2.7 × 104 CFU/100 ml for FC and 0 – 9.3 × 103 for EHEC CFU/100 ml, an indication of non-compliance with set guidelines. Preliminary identification of 40 randomly selected presumptive enterohemorrhagic E. coli isolates by Gram’s staining and oxidase test shows 100% (all 40 selected isolates) to be Gram positive while 90% (36 randomly selected isolates) were oxidase negative. Statistical correlation between the physicochemical and the microbiological parameters were generally weak except in the case of free chlorine and DO where they showed inverse correlation with the microbiological parameters. The recovery of EHEC showed the inefficiency of the treatment processes to effectively inactivate the bacteria, and possibly other pathogenic bacteria that may be present in the treated wastewater. The assessment suggested the need for proper monitoring and a review of the treatment procedures used at these treatment works.
- Full Text:
- Authors: Ajibade, Adefisoye Martins
- Date: 2014
- Subjects: Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11283 , http://hdl.handle.net/10353/d1016166 , Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Description: The production of final effluents that meet discharged requirements and guidelines remain a major challenge particularly in the developing world with the resultant problem of surface water pollution. This study assessed the physicochemical and microbiological qualities of two wastewater treatment works in the Eastern Cape Province of South Africa in terms of the prevalence of faecal coliforms and Escherichia coli O157:H7 over a five month period. All physicochemical and microbiological analyses were carried out using standard methods. Data were collected in triplicates and analysed statistically using IBM SPSS version 20.0. The ranges of some of the physicochemical parameters that complied with set guidelines include pH (6.7 – 7.6), TDS (107 – 171 mg/L), EC (168 – 266 μS/cm), Temperature (15 – 24oC), NO3- (0 – 8.2 mg/L), NO2- (0.14 – 0.71 mg/L) and PO4 (1.05 – 4.50 mg/L). Others including Turbidity (2.64 – 58.00 NTU), Free Cl (0.13 – 0.65 mg/L), DO (2.20 – 8.48 mg/L), BOD (0.13 – 6.85 mg/L) and COD (40 – 482 mg/L) did not comply with set guidelines. The microbiological parameters ranged 0 – 2.7 × 104 CFU/100 ml for FC and 0 – 9.3 × 103 for EHEC CFU/100 ml, an indication of non-compliance with set guidelines. Preliminary identification of 40 randomly selected presumptive enterohemorrhagic E. coli isolates by Gram’s staining and oxidase test shows 100% (all 40 selected isolates) to be Gram positive while 90% (36 randomly selected isolates) were oxidase negative. Statistical correlation between the physicochemical and the microbiological parameters were generally weak except in the case of free chlorine and DO where they showed inverse correlation with the microbiological parameters. The recovery of EHEC showed the inefficiency of the treatment processes to effectively inactivate the bacteria, and possibly other pathogenic bacteria that may be present in the treated wastewater. The assessment suggested the need for proper monitoring and a review of the treatment procedures used at these treatment works.
- Full Text:
Quality indices of the final effluents of two sub-urban-based wastewater treatment plants in Amathole District Municipality in the Eastern Cape Province of South Africa
- Authors: Gcilitshana, Onele
- Date: 2014
- Subjects: Whole effluent toxicity testing -- South Africa -- Eastern Cape , Sewage disposal plants -- South Africa -- Eastern Cape , Water -- Purification -- South Africa -- Eastern Cape , Effluent quality -- Testing , Viruses -- South Africa -- Eastern Cape , Water reuse -- South Africa -- Eastern Cape
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11288 , http://hdl.handle.net/10353/d1019816 , Whole effluent toxicity testing -- South Africa -- Eastern Cape , Sewage disposal plants -- South Africa -- Eastern Cape , Water -- Purification -- South Africa -- Eastern Cape , Effluent quality -- Testing , Viruses -- South Africa -- Eastern Cape , Water reuse -- South Africa -- Eastern Cape
- Description: Worldwide, water reuse is promoted as an alternative for water scarcity, however, wastewater effluents have been reported as possible contaminants to surface water. The failure of some wastewater treatment processes to completely remove organic matter and some pathogenic microorganisms allows them to initiate infections. This manifests more in communities where surface water is used directly for drinking. To assess water quality, bacteria alone cannot be used as it may be absent in virus-contaminated water. This study was carried out to assess the quality of two wastewater treatment plant effluents from the Eastern Cape Province of South Africa. Physicochemical parameters and microbiological parameters like faecal coliforms, adenovirus, rotavirus, hepatitis A virus, norovirus and enterovirus were evaluated over a projected period of one year. Physicochemical parameters were measured on site using multiparameters, faecal coliforms enumerated using culture-based methods and viruses are detected using both conventional and real-time PCR. Physicochemical parameters like electrical conductivity, turbidity, free chlorine and phosphates were incompliant with the standards set by the Department of Water affairs for effluents to be discharged. Faecal coliform counts were nil for one plant (WWTP-R) where they correlated inversely (P < 0.01) with the high free chlorine. For WWTP-K, faecal coliforms were detected in 27% of samples in the range of 9.9 × 101 to 6.4× 104 CFU/100ml. From the five viruses assessed, three viruses were detected with Rotavirus being the most abundant (0-2034176 genome copies/L) followed by Adenovirus (0–275 genome copies/L) then Hepatitis A virus (0–71 genome copies/L) in the WWTP-K while none of the viruses was detected in WWTP-R. Species B, species C and Adv41 serotypes were detected from the May 2013 and June 2013 samples where almost all parameters were incompliant in the plant. The detection of these viruses in supposedly treated effluents is suggestive of these being the sources of contamination to surface water and therefore renders surface waters unsafe for direct use and to aquatic life. Although real-time PCR is more sensitive and reliable in detection of viruses, use of cell-culture techniques in this study would have been more efficient in confirming the infectivity of the viruses detected, hence the recommendation of these techniques in future projects of this nature.
- Full Text:
- Authors: Gcilitshana, Onele
- Date: 2014
- Subjects: Whole effluent toxicity testing -- South Africa -- Eastern Cape , Sewage disposal plants -- South Africa -- Eastern Cape , Water -- Purification -- South Africa -- Eastern Cape , Effluent quality -- Testing , Viruses -- South Africa -- Eastern Cape , Water reuse -- South Africa -- Eastern Cape
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11288 , http://hdl.handle.net/10353/d1019816 , Whole effluent toxicity testing -- South Africa -- Eastern Cape , Sewage disposal plants -- South Africa -- Eastern Cape , Water -- Purification -- South Africa -- Eastern Cape , Effluent quality -- Testing , Viruses -- South Africa -- Eastern Cape , Water reuse -- South Africa -- Eastern Cape
- Description: Worldwide, water reuse is promoted as an alternative for water scarcity, however, wastewater effluents have been reported as possible contaminants to surface water. The failure of some wastewater treatment processes to completely remove organic matter and some pathogenic microorganisms allows them to initiate infections. This manifests more in communities where surface water is used directly for drinking. To assess water quality, bacteria alone cannot be used as it may be absent in virus-contaminated water. This study was carried out to assess the quality of two wastewater treatment plant effluents from the Eastern Cape Province of South Africa. Physicochemical parameters and microbiological parameters like faecal coliforms, adenovirus, rotavirus, hepatitis A virus, norovirus and enterovirus were evaluated over a projected period of one year. Physicochemical parameters were measured on site using multiparameters, faecal coliforms enumerated using culture-based methods and viruses are detected using both conventional and real-time PCR. Physicochemical parameters like electrical conductivity, turbidity, free chlorine and phosphates were incompliant with the standards set by the Department of Water affairs for effluents to be discharged. Faecal coliform counts were nil for one plant (WWTP-R) where they correlated inversely (P < 0.01) with the high free chlorine. For WWTP-K, faecal coliforms were detected in 27% of samples in the range of 9.9 × 101 to 6.4× 104 CFU/100ml. From the five viruses assessed, three viruses were detected with Rotavirus being the most abundant (0-2034176 genome copies/L) followed by Adenovirus (0–275 genome copies/L) then Hepatitis A virus (0–71 genome copies/L) in the WWTP-K while none of the viruses was detected in WWTP-R. Species B, species C and Adv41 serotypes were detected from the May 2013 and June 2013 samples where almost all parameters were incompliant in the plant. The detection of these viruses in supposedly treated effluents is suggestive of these being the sources of contamination to surface water and therefore renders surface waters unsafe for direct use and to aquatic life. Although real-time PCR is more sensitive and reliable in detection of viruses, use of cell-culture techniques in this study would have been more efficient in confirming the infectivity of the viruses detected, hence the recommendation of these techniques in future projects of this nature.
- Full Text:
- «
- ‹
- 1
- ›
- »